Background: Nephron sparing surgery is a well-established surgical procedure for patients with small/bilateral renal masses. During the procedure, hilar control can be achieved by using bulldog clamps individually on the renal vessels, the renal artery alone without clamping the vein, or a laparoscopic Satinsky clamp for en bloc hilar clamping. In our series, we described the outcome of laparoscopic nephron sparing surgery using a Satinsky clamp for hilar control.

Materials And Methods: All eligible cases with confirmed diagnosis of a renal mass were advised of nephron sparing surgery. The short-term outcomes were evaluated by warm ischemia time (using a Satinsky clamp especially when CT renal angiography was not available), average blood loss, and length of postoperative hospital stay. The oncological outcome was evaluated by noting the surgical margins of histopathological specimen, local recurrence, and distant metastasis.

Results: Of 30 cases 20 were male. The mean age was 54.25 years. On preoperative evaluation, 24 cases were T1a stage and the rest were 6 T1b stage. Four tumors were located in the upper pole, 4 in the posterior midpole, and 22 in the lower pole. Twenty-six patients had a low complexity score on RENAL scoring (ie, 4-6) and 4 patients a medium complexity score (ie, 7-9). Three patients were converted to open partial nephrectomy because of technical difficulty in intracorporeal suturing and difficulty in achieving hemostasis. Among these 3 patients, 2 patients had posterior base tumors and 1 had a lower polar tumor. Average blood loss was 350 ml, warm ischemia time was 28.46 minutes, and postoperative stay was 4.55 days. Of 30 specimens for histopathology, 23 (76%) were clear cell renal cell carcinoma (RCC), 4 (13%) were papillary RCC, 1 (3.3%) was chromophobe RCC, whereas 2 (6.6%) were benign (oncocytoma). Margins were free of tumors in all the patients with no recurrence in 2 years of follow-up.

Conclusion: Laparoscopic partial nephrectomy by using a Satinsky clamp as a tool for en bloc hilar clamping in the proper axis at the hilum takes care of multiple vessels irrespective of size and number, particularly when renal angiography is not available. This technique of en bloc hilar clamping is quite useful especially in developing countries where robotic facilities are not available. The Satinsky clamp decreases blood loss and intraoperative time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451325PMC
http://dx.doi.org/10.1097/CU9.0000000000000022DOI Listing

Publication Analysis

Top Keywords

satinsky clamp
24
nephron sparing
16
sparing surgery
16
bloc hilar
12
hilar clamping
12
blood loss
12
outcome laparoscopic
8
laparoscopic nephron
8
surgery satinsky
8
clamp hilar
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!