Introduction: Adjuvant radiation therapy (RT) following primary surgery in women affected by early breast cancer (EBC) plays a central role in reducing local recurrences and overall mortality. The FAST-FORWARD trial recently demonstrated that 1-week hypofractionated adjuvant RT is not inferior to the standard schedule in terms of local relapse, cosmetic outcomes and toxicity. The aim of this in silico study was to evaluate the dosimetric aspects of a 1-week RT course, administered through volumetric modulated arc therapy (VMAT), compared with traditional three-dimensional conformal radiation therapy (3D-CRT) with tangential fields.

Methods: Patients affected by left-side EBC undergoing adjuvant RT were selected. ESTRO guidelines for the clinical target volume (CTV) delineation and FAST-FORWARD protocol for CTV to planning target volume (PTV) margin definition were followed. Total prescribed dose was 26 Gy in five fractions. The homogeneity index (HI) and the global conformity index (GCI) were taken into account for planning and dose distribution optimisation purposes. Both 3D-CRT tangential fields and VMAT plans were generated for each patient.

Results: The analysis included 21 patients. PTV coverage comparison between 3D-CRT and VMAT plans showed significant increases for GCI (P < 0.05) in VMAT technique; no statistically significant differences were observed regarding HI. For organs at risks (OAR), statistically significant increases were observed in terms of skin V103% (P < 0.002) and ipsilateral lung V30% (P < 0.05) with 3D-CRT and of heart V5% (P < 0.05) with VMAT technique.

Conclusions: This in silico study showed that both 3D-CRT and VMAT are dosimetrically feasible techniques in the framework of 1-week hypofractionated treatments for left EBC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9163458PMC
http://dx.doi.org/10.1002/jmrs.530DOI Listing

Publication Analysis

Top Keywords

breast cancer
8
radiation therapy
8
3d-crt tangential
8
target volume
8
vmat plans
8
fractionations breast
4
cancer dosimetric
4
dosimetric study
4
3d-crt
4
study 3d-crt
4

Similar Publications

Ultrasound-responsive nanoparticles for nitric oxide release to inhibit the growth of breast cancer.

Cancer Cell Int

December 2024

Department of Ultrasound, Chongqing General Hospital, Chongqing University, Chongqing, 401147, China.

Gas therapy represents a promising strategy for cancer treatment, with nitric oxide (NO) therapy showing particular potential in tumor therapy. However, ensuring sufficient production of NO remains a significant challenge. Leveraging ultrasound-responsive nanoparticles to promote the release of NO is an emerging way to solve this challenge.

View Article and Find Full Text PDF

Targeting CDK2 to circumvent treatment resistance in HR breast cancer.

Trends Mol Med

December 2024

Cancer Signaling and Microenvironment Program, Fox Chase Cancer Center, Philadelphia, PA, USA. Electronic address:

Genetic and epigenetic defects of the p53 system have previously been associated with resistance to CDK4/6 inhibitors in women with HR breast cancer. Recent data from Kudo et al. demonstrate that CDK2-targeting agents may offer an effective strategy to circumvent such resistance by enforcing cellular senescence downstream of RBL2 dephosphorylation.

View Article and Find Full Text PDF

Dabrafenib upregulates hypoglycosylated MUC1 and improves the therapeutic efficacy of Tn-MUC1 CAR-T cells.

Sci Bull (Beijing)

December 2024

Breast Cancer Center, Zhejiang Cancer Hospital, Hangzhou Institute of Medicine (HIM), Chinese Academy of Sciences, Hangzhou, Zhejiang 310022, China. Electronic address:

View Article and Find Full Text PDF

Computational Pathology Detection of Hypoxia-Induced Morphological Changes in Breast Cancer.

Am J Pathol

December 2024

Department of Computer Science, Faculty of Engineering Sciences, University College London, Gower Street, London, WC1E 6BT, United Kingdom.

Understanding the tumor hypoxic microenvironment is crucial for grasping tumor biology, clinical progression, and treatment responses. This study presents a novel application of AI in computational histopathology to evaluate hypoxia in breast cancer. Weakly Supervised Deep Learning (WSDL) models can accurately detect morphological changes associated with hypoxia in routine Hematoxylin and Eosin (H&E) whole slide images (WSI).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!