Fast and effective methods are needed for sequencing of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) genome to track genetic mutations and to identify new and emerging variants during the ongoing pandemic. The objectives were to assess the performance of the SARS-CoV-2 AmpliSeq research panel and S5 plug-in analysis tools for whole-genome sequencing analysis of SARS-CoV-2 and to compare the results with those obtained with the MiSeq-based ARTIC analysis pipeline, using metrics such as depth, coverage, and concordance of single-nucleotide variant (SNV) calls. A total of 191 clinical specimens and a single cultured isolate were extracted and sequenced with AmpliSeq technology and analysis tools. Of the 191 clinical specimens, 83 (with threshold cycle [] values of 15.58 to 32.54) were also sequenced using an Illumina MiSeq-based method with the ARTIC analysis pipeline, for direct comparison. A total of 176 of the 191 clinical specimens sequenced on the S5XL system and prepared using the SARS-CoV-2 research panel had nearly complete coverage (>98%) of the viral genome, with an average depth of 5,031×. Similar coverage levels (>98%) were observed for 81/83 primary specimens that were sequenced with both methods tested. The sample with the lowest viral load ( value of 32.54) achieved 89% coverage using the MiSeq method and failed to sequence with the AmpliSeq method. Consensus sequences produced by each method were identical for 81/82 samples in areas of equal coverage, with a single difference present in one sample. The AmpliSeq approach is as effective as the Illumina-based method using ARTIC v3 amplification for sequencing SARS-CoV-2 directly from patient specimens across a range of viral loads ( values of 15.56 to 32.54 [median, 22.18]). The AmpliSeq workflow is very easily automated with the Ion Chef and S5 instruments and requires less training and experience with next-generation sequencing sample preparation than the Illumina workflow.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8601232PMC
http://dx.doi.org/10.1128/JCM.00649-21DOI Listing

Publication Analysis

Top Keywords

191 clinical
12
clinical specimens
12
whole-genome sequencing
8
sequencing sars-cov-2
8
ampliseq panel
8
analysis tools
8
artic analysis
8
analysis pipeline
8
method artic
8
specimens sequenced
8

Similar Publications

Background & Aim: Metabolic and cardiovascular health outcomes are strongly influenced by diet. Dietary habits established in early childhood may persist into adulthood. This study aimed to examine the association between dietary patterns at both 2 and 8 years of age, explaining the maximum variability of high- and low-quality fats, sugars, and fibre, and cardiometabolic markers at age 8 years.

View Article and Find Full Text PDF

Cannabis consumption and risk of asthma: a systematic review and meta-analysis.

BMC Pulm Med

January 2025

Global Health and Infectious Diseases Control Institute, Nasarawa State University, Keffi, Nigeria.

Background: Cannabis is the third most widely used psychoactive substance globally, and its consumption has been increasing, particularly with the growing trend of legalization for medicinal and recreational use. Recent studies have raised concerns about the potential impact of cannabis on respiratory health, specifically the risk of asthma, a significant public health concern. This systematic review aimed to consolidate research on the association between cannabis use and the risk of asthma.

View Article and Find Full Text PDF

Periapical bone edema volume in 3D MRI is positively correlated with bone architecture changes.

Insights Imaging

January 2025

Diagnostic and Interventional Radiology, University Hospital of Zurich, University Zurich, Zurich, Switzerland.

Objectives: To compare and correlate bone edema volume detected by 3D-short-tau-inversion-recovery (STIR) sequence to osseous decay detected by a T1-based sequence and conventional panoramic radiography (OPT).

Materials And Methods: Patients with clinical evidence of apical periodontitis were included retrospectively and received OPT as well as MRI of the viscerocranium including a 3D-STIR and a 3D-T1 gradient echo sequence. Bone edema was visualized using the 3D-STIR sequence and periapical hard tissue changes were evaluated using the 3D-T1 sequence.

View Article and Find Full Text PDF

The value of MRI in differentiating ovarian clear cell carcinoma from other adnexal masses with O-RADS MRI scores of 4-5.

Insights Imaging

January 2025

Department of Radiology, Shanghai First Maternity and Infant Hospital, School of Medicine, Tongji University, Shanghai, China.

Objective: To assess the utility of clinical and MRI features in distinguishing ovarian clear cell carcinoma (CCC) from adnexal masses with ovarian-adnexal reporting and data system (O-RADS) MRI scores of 4-5.

Methods: This retrospective study included 850 patients with indeterminate adnexal masses on ultrasound. Two radiologists evaluated all preoperative MRIs using the O-RADS MRI risk stratification system.

View Article and Find Full Text PDF

Prognostic Value of Coronary Angiography-Derived Index of Microcirculatory Resistance in Patients With Intermediate Coronary Stenosis.

JACC Cardiovasc Interv

January 2025

Department of Cardiology of The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, China; Cardiovascular Key Laboratory of Zhejiang Province, Hangzhou, China. Electronic address:

Background: The association between coronary microcirculation and clinical outcomes in patients with intermediate stenosis remains unclear.

Objectives: The aim of this study was to assess the prognostic significance of angiography-derived index of microcirculatory resistance (angio-IMR) in patients with intermediate coronary stenosis.

Methods: This post hoc analysis included 1,658 patients from the FLAVOUR (Fractional Flow Reserve and Intravascular Ultrasound for Clinical Outcomes in Patients with Intermediate Stenosis) trial, with angio-IMR measured in each vessel exhibiting intermediate stenosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!