A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dual-potential electrochemiluminescence from black phosphorus and graphitic carbon nitrides for label-free enzymatic biosensing. | LitMetric

Simultaneous anodic and cathodic electrochemiluminescence (ECL) emissions of black phosphorus nanosheets (BPNSs) and graphitic carbon nitrides (g-CN) were reported based on the co-existence of different co-reactants. Anodic ECL was obtained at the BPNSs modified electrode with tripropylamine (TPrA) as a co-reactant, while g-CN was selected as another emitter to obtain cathodic ECL emission with KSO as co-reactant. Employing the superiority of two separate ECL systems, a facile ECL method was developed for cholesterol detection based on cholesterol oxidase (ChOx) immobilized g-CNBPNSs modified glassy carbon electrode (g-CNBPNSs/GCE). False positive signals can be significantly reduced based on the separation of anode and cathode ECL signals from BPNSs and g-CN, respectively. The proposed biosensor provided a quantitative readout proportional to cholesterol concentrations in the range from 0.5 μM to 0.5 mM with a detection limit of 0.14 μM (cathodic system, 3, = 6) and 0.32 μM (anodic system, 3, = 6). The proposed biosensor demonstrated excellent analytical performance with remarkable sensitivity, manifesting its potential application in enzymatic biosensing field.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d1an01366aDOI Listing

Publication Analysis

Top Keywords

black phosphorus
8
graphitic carbon
8
carbon nitrides
8
enzymatic biosensing
8
proposed biosensor
8
ecl
6
dual-potential electrochemiluminescence
4
electrochemiluminescence black
4
phosphorus graphitic
4
nitrides label-free
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!