Purpose: To determine the diagnostic accuracy of potential screening tests for moderate to advanced glaucoma.

Design: Prospective diagnostic test accuracy study.

Participants: The study enrolled a consecutive series of patients aged ≥50 years who presented to a glaucoma clinic in South India without ever having received automated visual field testing.

Methods: All participants underwent 8 index tests: OCT of the peripapillary retinal nerve fiber layer, optic disc photography, Moorfield's Motion Displacement Test (MDT), frequency doubling technique perimetry, noncontact tonometry, pneumatonometry, presenting visual acuity, and best-corrected visual acuity. Participants also underwent stereoscopic photographs and Humphrey visual fields, which were used by 2 ophthalmologists to arrive at the reference standard diagnosis of moderate to advanced glaucoma.

Main Outcome Measures: Sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio.

Results: A total of 217 people were enrolled; 321 eyes from 180 participants had all tests performed. Of these, 127 eyes (40%) were classified as having moderate to advanced glaucoma. Among the 8 tests, OCT best optimized sensitivity (84%, 95% confidence interval [CI], 76-90) and specificity (75%, 95% CI, 68-81). Moorfield's Motion Displacement Test was the best perimetric test, with a sensitivity of 91% (95% CI, 85-96) and specificity of 53% (95% CI, 44-61). Pressure and vision tests were not sensitive (e.g., sensitivity of 16%, 95% CI, 9-23 for noncontact tonometry and 23%, 95% CI, 15-31 for best-corrected visual acuity). Moorfield's Motion Displacement Test identified 16 of 127 eyes (13%) with glaucoma that were not captured by OCT, but also had false-positive results in 65 of 194 eyes (34%) without glaucoma that OCT correctly classified as negative.

Conclusions: OCT had moderate sensitivity and fair specificity for diagnosing moderate to advanced glaucoma and should be prioritized during an initial assessment for glaucoma.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ogla.2021.09.005DOI Listing

Publication Analysis

Top Keywords

visual acuity
16
moderate advanced
12
moorfield's motion
12
motion displacement
12
displacement test
12
prospective diagnostic
8
diagnostic accuracy
8
participants underwent
8
tests oct
8
noncontact tonometry
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!