Distorted Copper(II) Complex with Unusually Short CF···Cu Distances.

Inorg Chem

Department of Chemistry, and Yale Energy Sciences Institute, Yale University, New Haven, Connecticut 06520-8107, United States.

Published: October 2021

We find a Cu(II)-() complex ( = 2,2,2-trifluoro--[2-(pyridin-2-yl)propan-2-yl]acetamide) with a distorted "seesaw" geometry. It has the shortest crystallographic CF···Cu distances yet reported, to the best of our knowledge (<2.6 Å), for which computational and experimental data indicate a secondary bonding interaction. A comparison with a CCl version and one without ligand backbone -dimethyl groups suggests a steric origin for the distorted geometry, resulting from the specific ligand interactions.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.inorgchem.1c01958DOI Listing

Publication Analysis

Top Keywords

cf···cu distances
8
distorted copperii
4
copperii complex
4
complex unusually
4
unusually short
4
short cf···cu
4
distances find
4
find cuii-
4
cuii- complex
4
complex 222-trifluoro--[2-pyridin-2-ylpropan-2-yl]acetamide
4

Similar Publications

There is a widespread perception that China's digital censorship distances its people from the global internet, and the Chinese Communist Party, through state-controlled media, is the main gatekeeper of information about foreign affairs. Our analysis of narratives about the Russo-Ukrainian War circulating on the Chinese social media platform Weibo challenges this view. Comparing narratives on Weibo with 8.

View Article and Find Full Text PDF

The diversity and heterogeneity of biomarkers has made the development of general methods for single-step quantification of analytes difficult. For individual biomarkers, electrochemical methods that detect a conformational change in an affinity binder upon analyte binding have shown promise. However, because the conformational change must operate within a nanometer-scale working distance, an entirely new sensor, with a unique conformational change, must be developed for each analyte.

View Article and Find Full Text PDF

Objective: The aim of this study is to test the feasibility of a custom 3D-printed guide for performing a minimally invasive cochleostomy for cochlear implantation.

Study Design: Prospective performance study.

Setting: Secondary care.

View Article and Find Full Text PDF

Super-resolution methods provide far better spatial resolution than the optical diffraction limit of about half the wavelength of light (∼200-300 nm). Nevertheless, they have yet to attain widespread use in plants, largely due to plants' challenging optical properties. Expansion microscopy improves effective resolution by isotropically increasing the physical distances between sample structures while preserving relative spatial arrangements and clearing the sample.

View Article and Find Full Text PDF

The shape characteristics of flow hydrographs hold essential information for understanding, monitoring and assessing changes in flow and flood hydrology at reach and catchment scales. However, the analysis of individual hydrographs is time consuming, making the analysis of hundreds or thousands of them unachievable. A method or protocol is needed to ensure that the datasets being generated, and the metrics produced, have been consistently derived and validated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!