This study aimed to a) determine whether wrist acceleration varies by accelerometer brand, wear location, and age for self-paced "slow", "normal" and "brisk" walking; b) develop normative acceleration values for self-paced walking and running for adults. One-hundred-and-three adults (40-79 years) completed self-paced "slow", "normal" and "brisk" walks, while wearing three accelerometers (GENEActiv, Axivity, ActiGraph) on each wrist. A sub-sample (n = 22) completed a self-paced run. Generalized estimating equations established differences by accelerometer brand, wrist, and age-group (walking only, 40-49, 50-59, 60-69, 70-79 years) for self-paced walking and running. Brand*wrist interactions showed ActiGraph dominant wrist values were ~10% lower than GENEActiv/Axivity values for walking and running, and non-dominant ActiGraph values were ~5% lower for running only (p < 0.001). Acceleration during brisk walking was lower in those aged 70-79 (p < 0.05). Normative acceleration values (non-dominant wrist, all brands; dominant wrist GENEActiv/Axivity) for slow and normal walking were 140 m and 210 m Brisk walking, values were 350 m in those aged 40-69 years, but 270 m in those aged 70-79 years. Accelerations >600 m approximated running. These values facilitate user-friendly interpretation of accelerometer-determined physical activity in large cohort and epidemiological datasets.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02640414.2021.1976491DOI Listing

Publication Analysis

Top Keywords

walking running
16
self-paced walking
12
values self-paced
8
accelerometer brand
8
self-paced "slow"
8
"slow" "normal"
8
"normal" "brisk"
8
completed self-paced
8
self-paced
6
walking
6

Similar Publications

Introduction: Gait analysis is a vital tool in the assessment of human movement and has been widely used in clinical settings to identify potential abnormalities in individuals. However, there is a lack of consensus on the normative values for gait metrics in large populations. The primary objective of this study is to establish a normative database of spatiotemporal gait metrics across various age groups, contributing to a broader understanding of human gait dynamics.

View Article and Find Full Text PDF

Comparison Between Water Aerobics and Deep-Water Running on Middle-Aged Adults' Anthropometric, Hemodynamic and Functional Outcomes.

Int J Environ Res Public Health

January 2025

Programa de Pós-Graduação em Educação Física, Centro de Desportos, Universidade Federal de Santa Catarina, Campus Universitário, Florianópolis 88040-900, SC, Brazil.

Background: Head-out aquatic training, using modalities such as water-aerobics/hydrogymnastics (HYD) and deep-water running (DWR), has been effective in improving the physical, metabolic and cognitive health of middle-aged adults. However, direct comparisons between these modalities are lacking.

Aim: The aim of this study was to compare the effects of water aerobics and deep-water running on anthropometric, functional and hemodynamic outcomes in adults and older adults.

View Article and Find Full Text PDF

Nanocellulose-toughened super-stretchable ionic conductive gel fibers for wearable strain sensors.

Int J Biol Macromol

January 2025

College of Textiles, Donghua University, Shanghai 201620, China; Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China. Electronic address:

In recent years, conductive gel materials have attracted extensive attention in the field of flexible electronics because of their excellent elasticity. When constructed as gel fibers, they can adapt to greater deformation, be woven, and be assembled with fabrics to make wearable smart devices without compromising comfort. However, gel fibers reported often exhibit insufficient mechanical properties and poor adaptability to different environment.

View Article and Find Full Text PDF

Background: We aimed to synthesize the kinematics and kinetics during landing and walking/running tasks of ankle copers compared with patients with chronic ankle instability and controls.

Methods: We systematically searched PubMed, CINAHL, SPORTDiscus, and Web of Science. Tri-planar lower extremity biomechanics (joint angle and moment at maximum and initial contact, and joint displacement) were synthesized using standard mean difference and 95 % confidence intervals.

View Article and Find Full Text PDF

Recognizing human body motions opens possibilities for real-time observation of users' daily activities, revolutionizing continuous human healthcare and rehabilitation. While some wearable sensors show their capabilities in detecting movements, no prior work could detect full-body motions with wireless devices. Here, we introduce a soft electronic textile-integrated system, including nanomaterials and flexible sensors, which enables real-time detection of various full-body movements using the combination of a wireless sensor suit and deep-learning-based cloud computing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!