Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The aim of the study was to test the reproducibility of performing conventional point shear wave elastography (pSWE), auto-pSWE, and ultrasound derived fat fraction (UDFF) in adult livers.
Methods: The Institutional Review Board approved the study and all participants provided written informed consent. Conventional pSWE (obtaining 10 measurements through 10 acquisitions), auto-pSWE (automatically obtaining 15 measurements by a single acquisition), and UDFF (one measurement obtained by one acquisition) of the liver were prospectively performed in 21 participants (10 men, 11 women, mean age 63y) by senior and junior operators in February-May 2021. Shear wave velocity (SWV, m/s) of the liver was measured by conventional pSWE and auto-pSWE. Intraclass correlation coefficient (ICC) and Bland-Altman limits of agreement were used to test intra-observer repeatability and inter-observer reproducibility in measuring pSWE, auto-pSWE, and UDFF.
Results: ICC for testing intra-observer repeatability and inter-observer reproducibility in performing pSWE, auto-pSWE, and UDFF was >0.85 (95% confidence interval 0.85-0.99). The mean difference of 95% Bland-Altman limits of agreement was -0.02 (upper 0.09, lower -0.12) and the correlation of SWV measured between conventional pSWE and auto-pSWE methods was strong (r = 0.87).
Conclusion: Our results suggest good repeatability and reproducibility in measuring UDFF and SWV in adult livers. The auto-pSWE has higher reliability, reproducibility and time efficacy in measuring SWV of adult livers when compared to conventional pSWE method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clinimag.2021.08.025 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!