Anterior segment OCT application in quantifying posterior capsule opacification severity with varied intraocular lens designs.

Int J Ophthalmol

Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Clinical College of Ophthalmology, Tianjin Medical University, Nankai University Eye Hospital, Tianjin 300020, China.

Published: September 2021

Aim: To evaluate the application of anterior segment-optical coherence tomography (AS-OCT) in posterior capsule opacification (PCO) severity assessment and analyse the relationship between PCO severity and intraocular lens (IOL) characters.

Methods: PCO patients were prospectively recruited. Cross-sectional images of the anterior segment at horizontal and vertical meridians were acquired with AS-OCT. The area of the IOL-PC (posterior capsular) space and PCO severity (area, thickness, and density at 3 mm and 5 mm IOL optic regions) were measured. The relationship between PCO severity and visual acuity, comparisons of PCO severity and IOL-PC space using varied IOL designs were analysed.

Results: One hundred PCO eyes were enrolled. IOL-PC space, PCO thickness and area were positively correlated with axial length. In addition, PCO area and thickness were positively correlated with visual acuity when it was ≤0.52 logMAR. The cut-off level of visual acuity should be 0.52 logMAR. With varied IOL designs, 3-piece C haptic IOL showed a smaller PCO area and thickness than the 1-piece 3 haptic IOL and 1-piece 4 haptic IOL. PCO area and thickness values for an IOL with a diameter ≤11.0 mm was greater than for an IOL with a diameter of 12.5 mm, and the differences were statistically significant. PCO area and thickness increased when IOL haptic angulation increased (from 0 to 12 degrees).

Conclusion: In PCO eyes, cut-off level of visual acuity is 0.52 logMAR. With more severe PCO, visual acuity maybe not enough to describe the visual function impairment. PCO severity and IOL-PC space are significantly correlated with axial length and IOL design and material.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8403866PMC
http://dx.doi.org/10.18240/ijo.2021.09.13DOI Listing

Publication Analysis

Top Keywords

pco severity
24
area thickness
20
visual acuity
20
pco area
16
pco
15
iol-pc space
12
haptic iol
12
iol
11
anterior segment
8
posterior capsule
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!