Aim: To evaluate the short-term clinical outcomes of Ferrara rings in keratoconus using an optimized nomogram developed after several years of research and retrospective analysis of clinical data.

Methods: This prospective longitudinal non-comparative clinical trial evaluated 88 eyes of 88 patients (age 18-62y) with keratoconus diagnosis from two Spanish centers. Ferrara ring segment (AJL Ophthalmic) implantation was performed in all cases, using the mechanical procedure in 25 eyes (28.4%) and a femtosecond laser-assisted procedure in 63 eyes (71.6%). The ring segments implanted in each case were selected using a new optimized nomogram that considered variables such as anterior corneal asphericity and astigmatism or the discrepancy among astigmatism and coma orientations. Visual, refractive, corneal topographic, aberrometric, and pachymetric changes after surgery were evaluated during a 3-month follow-up.

Results: The implants induced a significant refractive change as well as an improvement in uncorrected (UDVA) and corrected distance visual acuity (CDVA; <0.001). Postoperative CDVA of 0.10 logMAR or better was achieved in 28.4% and 46.5% of eyes, respectively. Two eyes (2.3%) lost two or more lines of CDVA whereas a total of 53.5% of eyes gained lines of CDVA. A significant central anterior and posterior corneal flattening was induced (≤0.003), with a significant reduction of anterior (<0.001) and posterior corneal astigmatisms (=0.048), and a change in anterior asphericity (<0.001). Total primary coma (6 mm pupil) change was also statistically significant (preoperative 3.66±3.04 µm postoperative 2.33±2.26 µm, <0.001). No significant differences were found in the effect of ring segments between cases implanted using the mechanical and femtosecond techniques (≥0.101).

Conclusion: The implantation of Ferrara rings based on the nomogram evaluated is safe and effective for promoting a visual rehabilitation in keratoconus, with a relevant control of primary coma aberration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8403859PMC
http://dx.doi.org/10.18240/ijo.2021.09.12DOI Listing

Publication Analysis

Top Keywords

ferrara ring
8
ring segment
8
optimized nomogram
8
procedure eyes
8
evaluation nomogram
4
nomogram ferrara
4
segment implantation
4
implantation keratoconus
4
keratoconus aim
4
aim evaluate
4

Similar Publications

R(3780) Resonance Interpreted as the 1^{3}D_{1}-Wave Dominant State of Charmonium from Precise Measurements of the Cross Section of e^{+}e^{-}→Hadrons.

Phys Rev Lett

December 2024

State Key Laboratory of Particle Detection and Electronics, Beijing 100049, Hefei 230026, People's Republic of China.

We report the precise measurements of the cross section of e^{+}e^{-}→hadrons at center-of-mass energies from 3.645 to 3.871 GeV.

View Article and Find Full Text PDF

Relationship Between Short-Term Blood Pressure Variability and Choroidal-Retinal Thicknesses Assessed by Optical Coherence Tomography in Hypertensive Subjects.

J Pers Med

November 2024

Unit of Nephrology and Dialysis, Hypertension Excellence Centre, Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties (PROMISE), Università di Palermo, 90128 Palermo, Italy.

The complications of hypertension depend not only on the mean blood pressure (BP) but also on its variability (BPV). Recent studies suggest that the choroid may serve as an indicator of systemic vascular damage. These studies have been made possible by the increased availability of optical coherence tomography (OCT).

View Article and Find Full Text PDF

Purpose: The metabolic pathways of APP-CHMINACA were characterized to select the markers of intake for implementation into analytical assays used by the clinical and forensic communities. We have combined the evidences obtained by both in vitro experiments and administration studies on mice.

Methods: APP-CHMINACA was incubated with either human or mouse liver microsomes.

View Article and Find Full Text PDF

Study of the Decay and Production Properties of D_{s1}(2536) and D_{s2}^{*}(2573).

Phys Rev Lett

October 2024

State Key Laboratory of Particle Detection and Electronics, Beijing 100049, Hefei 230026, People's Republic of China.

Article Synopsis
  • The study investigates the processes e^{+}e^{-}→D_{s}^{+}D_{s1}(2536)^{-} and e^{+}e^{-}→D_{s}^{+}D_{s2}^{*}(2573)^{-} using data from the BESIII detector, focusing on a range of center-of-mass energies.
  • For the first time, the absolute branching fractions of the decay processes for D_{s1}(2536)^{-} and D_{s2}^{*}(2573)^{-} are measured, revealing values of 35.9% and 37.4% respectively.
  • The research identifies a resonant structure around 4.6 Ge
View Article and Find Full Text PDF

Search for Rare Decays of D_{s}^{+} to Final States π^{+}e^{+}e^{-}, ρ^{+}e^{+}e^{-}, π^{+}π^{0}e^{+}e^{-}, K^{+}π^{0}e^{+}e^{-}, and K_{S}^{0}π^{+}e^{+}e^{-}.

Phys Rev Lett

September 2024

State Key Laboratory of Particle Detection and Electronics, Beijing 100049, Hefei 230026, People's Republic of China.

Article Synopsis
  • Scientists used special data from a detector to look for rare particle decays of a type called the D_{s}^{+} decay, focusing on how it might change into other particles like kaons or pions.
  • They found strong evidence for the decay D_{s}^{+}→π^{+}ϕ and also discovered a new decay D_{s}^{+}→ρ^{+}ϕ, both involving particles that decay into pairs of electrons.
  • However, they didn't find strong signals for three other types of decays they were looking for, and set limits on how often those changes could happen.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!