Objective: Magnetic resonance imaging (MRI) is increasingly used in the diagnosis of fetal malformations. The purpose of this study was to determine the diagnostic value of 1.5T MRI in fetal head and abdominal malformations.
Methods: A total of 132 pregnant women admitted to Shijiazhuang NO.4 Hospital were included and divided into a control group (CG; n=63) and a research group (RG; n=69) according to different prenatal examination methods. Patients in CG were given ultrasound, while those in RG underwent 1.5T MRI examination. The image quality of 1.5T MRI in different amniotic fluid, different gestational weeks with normal amniotic fluid and different fetal positions with normal amniotic fluid were compared. The detection rate and diagnostic value of the two methods were also compared, with the histological and pathological results as the gold standard.
Results: The image quality of 1.5T MRI was not affected by different gestational age with normal amniotic fluid, different fetal positions with normal amniotic fluid, or different amniotic fluid, indicating the feasibility of 1.5T MRI in fetal malformation examination. Histopathological diagnosis revealed 39 cases of head and abdominal deformities in CG and 50 cases in RG. Based on the results of ultrasound examination, there were 32 cases of deformities and 31 of non-deformities in CG. In RG, 1.5T MRI revealed 48 malformations and 21 non-malformations. The sensitivity, specificity, accuracy, missed diagnosis and misdiagnosis rates were 82.05%, 75.00%, 79.37%, 17.95% and 25.00% respectively in CG where ultrasonography was performed, and were 96.00%, 94.74%, 95.65%, 4.00% and 5.26% respectively in RG where 1.5T MRI was performed. The data identified significant differences in sensitivity, accuracy and missed diagnosis between RG and CG.
Conclusion: 1.5T MRI is effective in diagnosing fetal head and abdominal malformations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8430194 | PMC |
Clin Transl Radiat Oncol
March 2025
University Medical Center Utrecht, Department of Radiation Oncology, Utrecht, the Netherlands.
Background And Purpose: This study assessed the treatment time of online adaptive (i.e. Adapt-to-Shape, ATS) and virtual couch shift (i.
View Article and Find Full Text PDFDiagn Interv Imaging
January 2025
UFR Santé INSERM U1096, Rouen 76183, France; Department of Radiology and Medical Imaging (Cardiac Imaging Unit), CHU de Rouen Normandie, Hôpital Charles Nicolle, University of Rouen Normandie, Rouen 76000, France. Electronic address:
Purpose: The purpose of this study was to determine the normal variations of myocardial T1, T2, and T2* relaxation times on cardiac MRI obtained at 1.5 T in healthy, sex-balanced volunteers aged between 18 and 69 years.
Material And Methods: A total of 172 healthy volunteers were recruited prospectively.
J Cardiovasc Magn Reson
January 2025
Philips Healthcare, Beijing 100600, China.
Background: This study aims to identify optimal acceleration factors (AFs) for compressed sensing (CS) technology to enhance its clinical application for suspected coronary artery disease (CAD) in whole-heart non-contrast coronary magnetic resonance angiography (CMRA).
Methods: Two hundred and seventeen individuals with suspected CAD underwent whole-heart non-contrast CMRA on a 1.5-T CMR scanner with CS AFs of 2, 4, and 6 (CS2, CS4, and CS6).
Diagnostics (Basel)
January 2025
Arrow Program for Medical Research Education, Sheba Medical Center, Tel Hashomer, Ramat Gan 52621, Israel.
As medical imaging continues to expand, concerns about the potential risks of ionizing radiation to the developing fetus have led to a preference for non-radiation-based alternatives such as ultrasonography and fetal MRI. This review examines the current evidence on the safety of MRI during pregnancy, with a focus on 3 T MRI and contrast agents, aiming to provide a comprehensive synthesis that informs clinical decision-making, ensures fetal safety and supports the safe use of all available modalities that could impact management. We conducted a comprehensive review of studies from 2000 to 2024 on MRI safety during pregnancy, focusing on 3 T MRI and gadolinium use.
View Article and Find Full Text PDFPediatr Radiol
January 2025
University of Colorado Anschutz Medical Campus, 13001 E 17th Pl, Aurora, CO, 80045, USA.
Background: Intravoxel incoherent motion (IVIM) MRI uses diffusion-weighted (DW) MRI acquisitions to evaluate the microvascular and cellular environments of tissue. Due to these properties, IVIM has been increasingly utilized to evaluate abnormal placentation.
Objective: Our primary objective was to compare IVIM parameters in the placenta of patients with fetal growth restriction and appropriate for gestational age controls across gestational ages.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!