Objectives: In this international, multicenter study, using third-generation dual-source computed tomography (CT), we investigated the diagnostic performance of dynamic stress CT myocardial perfusion imaging (CT-MPI) in addition to coronary CT angiography (CTA) compared to invasive coronary angiography (ICA) and invasive fractional flow reserve (FFR).
Background: CT-MPI combined with coronary CTA integrates coronary artery anatomy with inducible myocardial ischemia, showing promising results for the diagnosis of hemodynamically significant coronary artery disease in single-center studies.
Methods: At 9 centers in Europe, Japan, and the United States, 132 patients scheduled for ICA were enrolled; 114 patients successfully completed coronary CTA, adenosine-stress dynamic CT-MPI, and ICA. Invasive FFR was performed in vessels with 25% to 90% stenosis. Data were analyzed by independent core laboratories. For the primary analysis, for each coronary artery the presence of hemodynamically significant obstruction was interpreted by coronary CTA with CT-MPI compared to coronary CTA alone, using an FFR of ≤0.80 and angiographic severity as reference. Territorial absolute myocardial blood flow (MBF) and relative MBF were compared using C-statistics.
Results: ICA and FFR identified hemodynamically significant stenoses in 74 of 289 coronary vessels (26%). Coronary CTA with ≥50% stenosis demonstrated a per-vessel sensitivity, specificity, and accuracy for the detection of hemodynamically significant stenosis of 96% (95% CI: 91%-100%), 72% (95% CI: 66%-78%), and 78% (95% CI: 73%-83%), respectively. Coronary CTA with CT-MPI showed a lower sensitivity (84%; 95% CI: 75%-92%) but higher specificity (89%; 95% CI: 85%-93%) and accuracy (88%; 95% CI: 84%-92%). The areas under the receiver-operating characteristic curve of absolute MBF and relative MBF were 0.79 (95% CI: 0.71-0.86) and 0.82 (95% CI: 0.74-0.88), respectively. The median dose-length product of CT-MPI and coronary CTA were 313 mGy·cm and 138 mGy·cm, respectively.
Conclusions: Dynamic CT-MPI offers incremental diagnostic value over coronary CTA alone for the identification of hemodynamically significant coronary artery disease. Generalized results from this multicenter study encourage broader consideration of dynamic CT-MPI in clinical practice. (Dynamic Stress Perfusion CT for Detection of Inducible Myocardial Ischemia [SPECIFIC]; NCT02810795).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8741746 | PMC |
http://dx.doi.org/10.1016/j.jcmg.2021.07.021 | DOI Listing |
J Surg Case Rep
January 2025
Department of Surgery, College of Health Sciences, Addis Ababa University, 1000 Addis Ababa, Ethiopia.
Deep femoral artery aneurysms are very rare; particularly when isolated and occur simultaneously in both limbs. We report such a case of a misdiagnosed 16-year-old male presenting after hematoma evacuation was attempted for painful swelling in the left groin. Once the diagnosis was confirmed by computed tomography angiography (CTA), an emergency aneurysmectomy with deep femoral artery (DFA) ligation was performed on the left limb.
View Article and Find Full Text PDFEur Radiol
December 2024
Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands.
Objectives: Screening for obstructive coronary artery disease (CAD) with coronary computed tomography angiography (CCTA) could prevent unnecessary invasive coronary angiography (ICA) procedures during work-up for trans-catheter aortic valve implantation (TAVI). CT-derived fractional flow reserve (CT-FFR) improves CCTA accuracy in chest pain patients. However, its reliability in the TAVI population is unknown.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
December 2024
Department of Surgery, University of North Dakota School of Medicine and Health Sciences, Grand Forks, North Dakota, United States.
Background: Despite advancements in valve implantation devices, vascular access complications (VAC) remain a significant cause of morbidity and mortality for those undergoing transcatheter aortic valve replacement (TAVR). We describe pre-operative imaging analysis of the aortoiliac and femoral arterial beds using the TransAtlantic intersociety consensus (TASC) score, ilio-femoral tortuosity, and procedural characteristics to identify anatomic risk factors predictive of VAC in TAVR.
Methods: Consecutive patients undergoing TAVR from 2012 to 2022 at a single North Dakota hospital were retrospectively reviewed.
J Cardiothorac Surg
December 2024
Department of Critical Care, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, 317000, China.
Background: Veno-arterial (V-A) extracorporeal membrane oxygenation (ECMO) is commonly used for patients with cardiac arrest, cardiogenic shock, or heart failure and is a life-saving technique. Computed tomography angiography (CTA) examination in patients on ECMO presents certain challenges. Due to the dual circulation characteristics of blood flow in ECMO patients, vascular imaging and interpretation can be difficult and may even present pitfalls.
View Article and Find Full Text PDFMed J Armed Forces India
December 2024
National Manager-Health System Strengthening, United Nations Development Program (UNDP), 55 Lodhi Estate, New Delhi, India.
Background: The purpose of this paper is to compare the efficacy of dual-phase multidetector computed tomography angiography (CTA) with transthoracic echocardiogram (TTE) and cardiac catheterization angiography (CCA) in evaluation of pulmonary arteries and collateral vessels, major aortopulmonary collateral arteries (MAPCAs) in children with cyanotic congenital heart diseases.
Methods: The study was a prospective observational study where 32 pediatric patients (18 males, 14 females and age range 2-116 months) with cyanotic congenital heart diseases (CCHD) were included. All patients underwent TTE, CTA, and CCA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!