Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction/objective: Liquid-based cytology (LBC) is advantageous as multiple stained specimens can be prepared and used for additional assays such as immunocytochemical and molecular-pathological investigations. Two types of preservative-fixative solutions (fixatives) are used for nongynecologic specimens used in the BD SurePath-LBC (SP-LBC) method, and their components vary. However, few studies have evaluated the differences in antigen-retaining ability between these fixatives. Therefore, we investigated and compared the antigen-retaining ability of the fixatives in immunocytochemical staining (ICC) under long-term storage conditions.
Materials And Methods: Sediments of cultured RAJI cells (derived from Burkitt's lymphoma) were added to each fixative (red and blue) and stored at room temperature for a specified period (1 h; 1 week; and 1, 3, and 6 months). The specimens were then prepared using the SP-LBC method and subjected to ICC. Positivity rate was calculated using the specimens fixed at room temperature for 1 h as a control. Antibodies against Ki67 expressed in the nucleus and against CD20 and leukocyte common antigen (LCA) expressed on the cell membrane were used.
Results: For CD20 and LCA, the positivity rate increased with time in the red fixative compared with that in the control. In the blue fixative, the positivity rate was highest at 1 h and was maintained at a high level throughout the storage period. In contrast, the Ki67 positivity rate was highest at 1 h in both red and blue fixatives and markedly decreased with time. Therefore, although refrigerated (8°C) storage was used, no improvement was noted.
Conclusions: Long-term storage is possible for cell membrane antigens at room temperature; however, it is unsuitable for intranuclear antigens. Therefore, we conclude that suitable fixative type and storage temperature differ based on antigen location. Further investigation is warranted.