Multiplexed all-solid-state ion-sensitive light-addressable potentiometric sensor (ISLAPS) system based on silicone-rubber for physiological ions detection.

Anal Chim Acta

Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China. Electronic address:

Published: September 2021

Light-addressable potentiometric sensor (LAPS) has been widely used in biomedical applications since its advent. As a member of the potentiometric sensors, ion-sensitive LAPS (ISLAPS) can be obtained by modifying ion selective sensing membrane on the sensor surface. Compared with the conventional ion-selective electrodes (ISEs) with liquid contact, the all-solid-state ISEs have more advantages such as easy maintenance, more convenient for miniaturization and practical applications. However, the commonly used ion-sensitive membrane (ISM) matrix like PVC has many limitations such as poor adhesion to silicone-based sensor and easy overflow of the plasticizer from the membrane. In this work, LAPS was combined with a variety of ionophore-doped all-solid-state silicone-rubber ISMs for the first time, to establish a program-controlled multiplexed ISLAPS system for physiological ions (Na, K, Ca and H) detection. The silicone-rubber ISMs have better adhesion to silicon-based sensors without containing plasticizers, which can avoid the plasticizer pollution and improve the long-term stability. A layer of poly(3-octylthiophene-2,5-diyl) (P3OT) was pre-modified on the sensor surface to inhibit the formation of an aqueous layer and improve the sensor lifetime. With the aid of a translation stage, the light spot automatically illuminated the detection sites in sequence, and the response of the four ions could be obtained in one measurement within 1 min. The proposed multiplexed ISLAPS has good sensitivity with micromolar limit of detection (LOD), good selectivity and long-term stability (more than 3 months). The results of the real Dulbecco's Modified Eagle Medium (DMEM) sample detection proved that the ISLAPS system can be used for the physiological ions detection, and is promising to realize a multi-parameter microphysiometer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2021.338603DOI Listing

Publication Analysis

Top Keywords

islaps system
12
physiological ions
12
ions detection
12
light-addressable potentiometric
8
potentiometric sensor
8
sensor surface
8
silicone-rubber isms
8
multiplexed islaps
8
system physiological
8
long-term stability
8

Similar Publications

Multiplexed all-solid-state ion-sensitive light-addressable potentiometric sensor (ISLAPS) system based on silicone-rubber for physiological ions detection.

Anal Chim Acta

September 2021

Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China. Electronic address:

Light-addressable potentiometric sensor (LAPS) has been widely used in biomedical applications since its advent. As a member of the potentiometric sensors, ion-sensitive LAPS (ISLAPS) can be obtained by modifying ion selective sensing membrane on the sensor surface. Compared with the conventional ion-selective electrodes (ISEs) with liquid contact, the all-solid-state ISEs have more advantages such as easy maintenance, more convenient for miniaturization and practical applications.