Reproducibility and responsiveness of the Frailty Index and Frailty Phenotype in older hospitalized patients.

BMC Geriatr

Department of Internal Medicine and Geriatrics, University of Groningen, University Medical Center Groningen, PO Box 30001, HPC: AA43, 9700 RB, Groningen, The Netherlands.

Published: September 2021

Background: There is growing interest for interventions aiming at preventing frailty progression or even to reverse frailty in older people, yet it is still unclear which frailty instrument is most appropriate for measuring change scores over time to determine the effectiveness of interventions. The aim of this prospective cohort study was to determine reproducibility and responsiveness properties of the Frailty Index (FI) and Frailty Phenotype (FP) in acutely hospitalized medical patients aged 70 years and older.

Methods: Reproducibility was assessed by Intra-Class Correlation Coefficients (ICC), standard error of measurement (SEM) and smallest detectable change (SDC); Responsiveness was assessed by the standardized response mean (SRM), and area under the receiver operating characteristic curve (AUC).

Results: At baseline, 243 patients were included with a median age of 76 years (range 70-98). The analytic samples included 192 and 187 patients in the three and twelve months follow-up analyses, respectively. ICC of the FI were 0.85 (95 % confidence interval [CI]: 0.76; 0.91) and 0.84 (95% CI: 0.77; 0.90), and 0.65 (95% CI: 0.49; 0.77) and 0.77 (95% CI: 0.65; 0.84) for the FP. SEM ranged from 5 to 13 %; SDC from 13 to 37 %. SRMs were good in patients with unchanged frailty status (< 0.50), and doubtful to good for deteriorated and improved patients (0.43-1.00). AUC's over three months were 0.77 (95% CI: 0.69; 0.86) and 0.71 (95% CI: 0.62; 0.79) for the FI, and 0.68 (95% CI: 0.58; 0.77) and 0.65 (95% CI: 0.55; 0.74) for the FP. Over twelve months, AUCs were 0.78 (95% CI: 0.69; 0.87) and 0.82 (95% CI: 0.73; 0.90) for the FI, and 0.78 (95% CI: 0.69; 0.87) and 0.75 (95% CI: 0.67; 0.84) for the FP.

Conclusions: The Frailty Index showed better reproducibility and responsiveness properties compared to the Frailty Phenotype among acutely hospitalized older patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8447764PMC
http://dx.doi.org/10.1186/s12877-021-02444-yDOI Listing

Publication Analysis

Top Keywords

reproducibility responsiveness
8
frailty
8
frailty frailty
8
frailty phenotype
8
patients
5
responsiveness frailty
4
phenotype older
4
older hospitalized
4
hospitalized patients
4
patients background
4

Similar Publications

A New Approach to Non-Invasive Microcirculation Monitoring: Quantifying Capillary Refill Time Using Oximetric Pulse Waves.

Sensors (Basel)

January 2025

Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.

(1) Background: To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2) Methods: Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues.

View Article and Find Full Text PDF

: Accurate and reproducible spleen volume measurements are essential for assessing treatment response and disease progression in myelofibrosis. This study evaluates techniques for measuring spleen volume on abdominal MRI. : In 20 patients with bone marrow biopsy-proven myelofibrosis, 5 observers independently measured spleen volume on 3 abdominal MRI pulse sequences, 3D-spoiled gradient echo T1, axial single-shot fast spin echo (SSFSE) T2, and coronal SSFSE T2, using ellipsoidal approximation, manual contouring, and 3D nnU-Net model-assisted contouring comparing coefficients of variation.

View Article and Find Full Text PDF

Lipid peroxidation is a major process that determines the quality of various oil samples during their use and storage, in which the primary products are hydroperoxides (HP'). HP' are very stable compounds at ambient conditions and are harmful to human health. Therefore, the evaluation of the degree of oil oxidation is an excellent tool for ensuring food safety.

View Article and Find Full Text PDF

: Developing ex vivo models that replicate immune-tumor interactions with high fidelity is essential for advancing immunotherapy research, as traditional two-dimensional in vitro systems often lack the complexity required to fully represent these interactions. : In this study, we establish a comprehensive 3D redirect lysis (3D-RDL) assay using colorectal cancer spheroids and adult stem cell-derived, healthy human organoids to evaluate the efficacy and safety profile of , a bispecific antibody targeting carcinoembryonic antigens (CEAs) on cancer cells and CD3 on T cells. This model allows us to assess cytotoxic activity and immune responses, capturing variations in therapeutic response not observable in simpler systems.

View Article and Find Full Text PDF

Situational factors can influence cognitive performance and should be considered for conducting cognitive assessments. The objective of this project was to develop a checklist for Cognitive Assessment Requirements (CARE) to identify these situational factors before conducting cognitive assessments and account for them. This study employed a four-round Delphi approach involving 22 experts to identify situational factors that can impact cognitive assessment results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!