Reliability and reproducibility of an automatic ambulatory blood pressure recorder (ICR-5200, Squibb) were tested on 45 subjects (24 normotensives and 21 hypertensives) aged 32-64 (mean age 49). Of 6,566 recordings, 2,376 measurements were cross-checked with a Riva Rocci sphygmomanometer in supine, standing, or sitting position at the beginning and at the end of a 24-hour monitoring period. Moreover, in 11 normotensives and in 11 hypertensives, cross-checking was performed during a cycloergometer effort test. A highly significant linear correlation was found in all the conditions tested (r = 0.98, p less than 0.001 for systolic and r = 0.98, p less than 0.001 for diastolic pressure) either in hypertensives or in normotensives. Only 8% of diastolic measurements performed by the two methods differed more than 5 mmHg. For each subject 5.4 +/- 3.8% of the preprogrammed measurements were lost. Only seven out of 45 subjects referred a disturbed sleep. ICR-5200 seems a suitable and reliable tool for automatic blood-pressure recording.
Download full-text PDF |
Source |
---|
Sensors (Basel)
January 2025
Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.
(1) Background: To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2) Methods: Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues.
View Article and Find Full Text PDFAsia Pac J Clin Nutr
February 2025
Department of Food and Nutrition, Gangneung-Wonju National University, Gangneung-si, Gangwon State, Republic of Korea. Email:
Background And Objectives: This study investigated the influence of dietary intake on the relationship between serum uric acid (SUA) levels and the risk of hypertension.
Methods And Study Design: Data from the 7th and 8th Korean National Health and Nutrition Examination Survey, a nationally representative survey, were analyzed. A total of 19,140 adults aged 19-64 years were included.
Cardiovasc Eng Technol
January 2025
Department of Research and Development, Nonprofit Organization of Research Institute of Life Benefit, Sapporo, Hokkaido, 005-0006, Japan.
Purpose: Dysfunction of vasomotor reactions due to arteriolar smooth muscle causes serious adverse events, such as loss of hemodynamic coherence. This in turn can increase risks of cardiovascular-related diseases. A noninvasive and quantitative evaluation of microvascular disorder is therefore very important for early diagnosis and treatment.
View Article and Find Full Text PDFJ Clin Hypertens (Greenwich)
January 2025
Department of Geriatrics, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China.
Red blood cell distribution width (RDW) has recently been recognized as a novel biomarker associated with various cardiovascular conditions. This study aims to investigate the relationship between RDW and carotid-femoral pulse wave velocity (cfPWV) in a southern Chinese population. A total of 4916 patients were initially enrolled from the First Affiliated Hospital of Fujian Medical University between January 2016 and December 2022.
View Article and Find Full Text PDFArch Dis Child
January 2025
Murdoch Children's Research Institute, Parkville, Victoria, Australia.
Objective: The aim of this study was to evaluate the acceptability and feasibility of home-based blood pressure (BP) screening in a group of paediatric patients with known elevated risk of developing hypertension.
Design: Cross-sectional study.
Setting: Specialist outpatient clinic and patient homes.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!