Objective: To characterize viscoelastic testing profiles of children with multisystem inflammatory syndrome in children (MIS-C).
Methods: This single-center retrospective review included 30 patients diagnosed with MIS-C from March 1 to September 1, 2020. Thromboelastography (TEG) with platelet mapping was performed in 19 (63%) patients and compared to age- and sex-matched controls prior to cardiac surgery. Relationships between TEG parameters and inflammatory markers were assessed using correlation.
Results: Patients with MIS-C had abnormal TEG results compared to controls, including decreased kinetic (K) time (1.1 vs. 1.7 minutes, p < .01), increased alpha angle (75.0° vs. 65.7°, p < .01), increased maximum amplitude (70.8 vs. 58.3 mm, p < .01), and decreased lysis in 30 minutes (Ly30) (1.1% vs. 3.7%, p = .03); consistent with increased clot formation rate and strength, and reduced fibrinolysis. TEG maximum amplitude was moderately correlated with erythrocyte sedimentation rate (ESR) (r = 0.60, p = .02), initial platelet count (r = 0.67, p < .01), and peak platelet count (r = 0.51, p = .03). TEG alpha angle was moderately correlated with peak platelet count (r = 0.54, p = .02). Seventeen (57%) patients received aspirin (ASA) and anticoagulation, five (17%) received only ASA, and three (10%) received only anticoagulation. No patients had a symptomatic thrombotic event. Six (20%) patients had a bleeding event, none of which was major.
Conclusions: Patients with MIS-C had evidence of hypercoagulability on TEG. Increased ESR and platelets were associated with higher clot strength. Patients were prophylactically treated with ASA or anticoagulation with no symptomatic thrombosis or major bleeding. Further multicenter study is required to characterize the rate of thrombosis and optimal thromboprophylaxis algorithm in this patient population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/pbc.29355 | DOI Listing |
Ann Intensive Care
January 2025
Department of Anesthesiology, Critical Care, and Surgery, Duke University School of Medicine, Durham, NC, USA.
Transfus Med
January 2025
Research and Development, Finnish Red Cross Blood Service, Vantaa, Finland.
Background: Extracellular vesicles (EVs) have procoagulative properties. As EVs are known to accumulate in stored blood products, we compared the EV content and coagulation capacity of leukoreduced cold-stored whole blood (CSWB) with current prehospital and in-hospital component therapies to understand the role of EVs in the haemostatic capacity of ageing CSWB.
Materials And Methods: Blood was obtained from 12 O RhD-positive male donors.
Sensors (Basel)
January 2025
Institute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Straße 66, 38106 Braunschweig, Germany.
A novel piezoresistive cantilever microprobe (PCM) with an integrated electrothermal or piezoelectric actuator has been designed to replace current commercial PCMs, which require external actuators to perform contact-resonance imaging (CRI) of workpieces and avoid unwanted "forest of peaks" observed at large travel speed in the millimeter-per-second range. Initially, a PCM with integrated resistors for electrothermal actuation (ETA) was designed, built, and tested. Here, the ETA can be performed with a piezoresistive Wheatstone bridge, which converts mechanical strain into electrical signals by boron diffusion in order to simplify the production process.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
CITAB-Centre for the Research and Technology of Agro-Environmental and Biological Sciences, School of Science and Technology, University of Trás-os-Montes and Alto Douro, 5000-801 Vila Real, Portugal.
Epoxy resins are extensively employed as adhesives and matrices in fibre-reinforced composites. As polymers, they possess a viscoelastic nature and are prone to creep and stress relaxation even at room temperature. This phenomenon is also responsible for time-dependent failure or creep fracture due to cumulative strain.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
Department of Civil Engineering, University of Texas Rio Grande Valley, Edinburg, TX 78539, USA.
This paper focuses on the theoretical and analytical modeling of a novel seismic isolator termed the Passive Friction Mechanical Metamaterial Seismic Isolator (PFSMBI) system, which is designed for seismic hazard mitigation in multi-story buildings. The PFSMBI system consists of a lattice structure composed of a series of identical small cells interconnected by layers made of viscoelastic materials. The main function of the lattice is to shift the fundamental natural frequency of the building away from the dominant frequency of earthquake excitations by creating low-frequency bandgaps (FBGs) below 20 Hz.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!