To assess the distribution of axial length as surrogate for myopia and its determinants in an old population, we performed the Ural Very Old Study as a population-based cohort study. Out of 1882 eligible individuals aged 85 + years, the Ural Very Old Study performed in an urban and rural region in Bashkortostan/Russia included 1526 (81.1%) individuals undergoing ophthalmological and medical examinations with sonographic axial length measurement. Biometric data were available for 717 (47.0%) individuals with a mean age of 88.0 ± 2.6 years (range 85-98 years; 25%). Mean axial length was 23.1 ± 1.1 mm (range 19.37-28.89 mm). Prevalences of moderate myopia (axial length 24.5-< 26.5 mm) and high myopia (axial length ≥ 26.5 mm) were 47/717 (6.6%; 95% CI 4.7, 8.4) and 10/717 (1.4%; 95% CI 0.5, 2.3), respectively. In multivariable analysis, longer axial length was associated (coefficient of determination r 0.25) with taller body height (standardized regression coefficient beta:0.16;non-standardized regression coefficient B: 0.02; 95% confidence interval (CI) 0.01, 0.03; P < 0.001), higher level of education (beta: 0.12; B: 0.07; 95% CI 0.02, 0.11; P = 0.002), and lower corneal refractive power (beta: - 0.35; B: - 0.23; 95% CI - 0.28, - 0.18; P < 0.001). Higher prevalence of moderate myopia, however not of high myopia, was associated with higher educational level (OR 1.39; 95% CI 1.09, 1.68; P = 0.007) and lower corneal refractive power (OR 0.77; 95% CI 0.63, 0.94; P = 0.01). In this old study population, prevalence of moderate axial myopia (6.6% versus 9.7%) was lower than, and prevalence of high axial myopia (1.4% versus 1.4%) was similar as, in a corresponding study on a younger population from the same Russian region. Both myopia prevalence rates were higher than in rural Central India (1.5% and 0.4%, respectively). As in other, younger, populations, axial length and moderate myopia prevalence increased with higher educational level, while high myopia prevalence was independent of the educational level.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8446056PMC
http://dx.doi.org/10.1038/s41598-021-98039-zDOI Listing

Publication Analysis

Top Keywords

axial length
20
ural study
12
axial
5
length associations
4
associations ural
4
study
4
study assess
4
assess distribution
4
distribution axial
4
length
4

Similar Publications

Purepose: The intraoperative femtosecond laser time, Cumulative Dissipated Energy (CDE), Effective Phacoemulsification time (EPT), and intraoperative fluid perfusion volume were compared under different model fragmentation modes using Catalys femtosecond laser system.

Methods: This was a single-center, prospective, randomized controlled study. A total of 120 eyes who underwent femtosecond laser-assisted cataract phacoemulsification combined with intraocular lens implantation in Xiamen Eye Center affiliated to Xiamen University from September 2022 to March 2023 were randomly divided into 4 groups to undergo pre-nucleus splitting in different ways: Group 1: six-split, Group 2: eight-split, Group 3: six-split + gridded softening, and Group 4: eight-split + gridded softening.

View Article and Find Full Text PDF

Relative anterior microphthalmos (RAM) is a rare ocular condition characterized by disproportionately small anterior segments but normal axial length (corneal diameter < 11 mm and axial length > 20 mm). This study aimed to determine the prevalence of RAM and its association with glaucoma utilizing IOL Master 700 data (Carl Zeiss Meditec, Jena, Germany). A retrospective analysis was conducted of the biometric parameters of 6,407 eyes, and 115 cases of RAM were identified.

View Article and Find Full Text PDF

To observe the structural changes of retina and choroid in patients with different degrees of myopia. We recruited 219 subjects with different degrees of myopia for best corrected visual acuity, computer refraction, intraocular pressure, axial length (AL), optical coherence tomography (OCT) imaging, and other examinations. Central macular retinal thickness (CRT), subfoveal choroidal thickness (SFCT), nasal retinal thickness (NRT), temporal retinal thickness (TRT), nasal choroidal thickness (NCT) and temporal choroidal thickness (TCT) were measured by optical coherence tomography.

View Article and Find Full Text PDF

We developed a simple quantifiable scoring system that predicts aneurysmal subarachnoid hemorrhage (aSAH) mortality, delayed cerebral ischemia (DCI), and modified Rankin scale (mRS) outcomes using readily available SAH admission data with SAH volume (SAHV) measured on computed tomography (CT). We retrospectively analyzed a cohort of 277 patients with aSAH admitted at our Comprehensive Stroke Center at Mayo Clinic in Jacksonville, Florida, between January 5, 2012, and February 24, 2022. We developed a mathematical radiographic model SAHV that measures basal cisternal SAH blood volume using a derivation of the ABC/2 ellipsoid formula (A = width/thickness, B = length, C = vertical extension) on noncontrast CT, which we previously demonstrated is comparable to pixel-based manual segmentation on noncontrast CT.

View Article and Find Full Text PDF

Purpose: This study aims to assess the effectiveness of atropine 0.05% for myopia control among children exhibiting (documented) rapid myopia progression (>0.75D/year).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!