It is likely that when using an artificially augmented hand with six fingers, the natural five plus a robotic one, corticospinal motor synergies controlling grasping actions might be different. However, no direct neurophysiological evidence for this reasonable assumption is available yet. We used transcranial magnetic stimulation of the primary motor cortex to directly address this issue during motor imagery of objects' grasping actions performed with or without the Soft Sixth Finger (SSF). The SSF is a wearable robotic additional thumb patented for helping patients with hand paresis and inherent loss of thumb opposition abilities. To this aim, we capitalized from the solid notion that neural circuits and mechanisms underlying motor imagery overlap those of physiological voluntary actions. After a few minutes of training, healthy humans wearing the SSF rapidly reshaped the pattern of corticospinal outputs towards forearm and hand muscles governing imagined grasping actions of different objects, suggesting the possibility that the extra finger might rapidly be encoded into the user's body schema, which is integral part of the frontal-parietal grasping network. Such neural signatures might explain how the motor system of human beings is open to very quickly welcoming emerging augmentative bioartificial corticospinal grasping strategies. Such an ability might represent the functional substrate of a final common pathway the brain might count on towards new interactions with the surrounding objects within the peripersonal space. Findings provide a neurophysiological framework for implementing augmentative robotic tools in humans and for the exploitation of the SSF in conceptually new rehabilitation settings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8445932 | PMC |
http://dx.doi.org/10.1038/s41598-021-97876-2 | DOI Listing |
J Neural Eng
January 2025
University of Pittsburgh, 1622 Locust St, Pittsburgh, Pennsylvania, 15219, UNITED STATES.
Real-world implementation of brain-computer interfaces (BCI) for continuous control of devices should ideally rely on fully asynchronous decoding approaches. That is, the decoding algorithm should continuously update its output by estimating the user's intended actions from real-time neural activity, without the need for any temporal alignment to an external cue. This kind of open-ended temporal flexibility is necessary to achieve naturalistic and intuitive control, but presents a challenge: how do we know when it is appropriate to decode anything at all? Activity in motor cortex is dynamic and modulates with many different types of actions (proximal arm control, hand control, speech, etc.
View Article and Find Full Text PDFWaste Manag
January 2025
ZheJiang University, Department of Mechanical Engineering, ZheJiang, 310000, China.
With the rapid increase in end-of-life smartphones, enhancing the automation and intelligence of their recycling processes has become an urgent challenge. At present, the disassembly of discarded smartphones predominantly relies on manual labor, which is not only inefficient but also associated with environmental pollution and high labor intensity. In the context of end-of-life smartphone recycling, complex situations such as stacking and occlusion are commonly encountered.
View Article and Find Full Text PDFRMD Open
January 2025
Health Services Research and Innovation Unit, Diakonhjemmet Hospital, Oslo, Norway.
Background: We aimed to update the 2018 systematic literature review on the efficacy and safety of treatments for hand osteoarthritis (OA), which was based on 126 studies.
Methods: We performed a systematic literature search on randomised controlled trials from June 2017 up to 31 December 2023. Risk of bias was assessed using the RoB2 tool.
Shoulder Elbow
January 2025
MGM Institute of Health Sciences School of Physiotherapy, MGM School of Physiotherapy, Navi Mumbai, Maharashtra, India.
Background: Hand grip strength is a critical indicator of upper extremity function, especially important in healthcare professions. Effective upper extremity function relies on proximal stability from the scapula and distal mobility from hand actions. This study aimed to examine the relationship between scapular dyskinesia and hand grip strength in healthcare students with smartphone addiction.
View Article and Find Full Text PDFCarbohydr Polym
March 2025
College of Chemistry, Zhengzhou University, Zhengzhou 450000, China. Electronic address:
Soft actuators for intelligent robots require further elaboration to improve their biomedical applicability, which has led to the development of a series of flexible stimulus-responsive materials. However, fabricating degradable soft actuators that exhibit synergistic color and shape changes in response to environmental stimuli remains challenging. Here, we developed a soft actuating gel based on carbon dots (CDs) that are chemically cross-linked with sodium alginate.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!