Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Endobronchial ultrasound (EBUS) bronchoscopy is an established minimally-invasive modality for visualization, characterization, and guidance of sampling of paratracheal and parabronchial structures and tissues. In the intensive care unit (ICU), rapidly obtaining an accurate diagnosis is paramount to the management of critically ill patients. In some instances, diagnosing and confirming terminal illness in a critically ill patient provides needed closure for patients and their loved ones. Currently available data on feasibility, safety, and yield of EBUS bronchoscopy in critically ill patients is based on single center experiences. These data suggest that in select ICU patients convex and radial probe-EBUS bronchoscopy can serve as useful tools in the evaluation of mediastinal lymphadenopathy, central airway obstruction, pulmonary embolism, and peripheral lung lesions. Barriers to the use of EBUS bronchoscopy in the ICU include: (I) requirement for dedicated equipment, prolonged procedure time, and bronchoscopy team expertise that may not be available; (II) applicability to a limited number of patients and conditions in the ICU; and (III) technical difficulty related to the relatively large outer diameter of the convex probe-EBUS bronchoscope and an increased risk for adverse cardiopulmonary consequences due to intermittent obstruction of the artificial airway. While the prospects for EBUS bronchoscopy in critically ill patients appear promising, judicious patient selection in combination with bronchoscopy team expertise are of utmost importance when considering performance of EBUS bronchoscopy in the ICU setting.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8411164 | PMC |
http://dx.doi.org/10.21037/jtd-2019-ipicu-09 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!