We describe a high-performance, compact optical frequency standard based on a microfabricated Rb vapor cell and a low-noise, external cavity diode laser operating on the Rb two-photon transition at 778 nm. The optical standard achieves an instability of 1.8×10 for times less than 100 s and a flicker noise floor of 1×10 out to 6000 s. At long integration times, the instability is limited by variations in optical probe power and the ac Stark shift. The retrace was measured to 5.7×10 after 30 h of dormancy. Such a simple, yet high-performance optical standard could be suitable as an accurate realization of the meter or, if coupled with an optical frequency comb, as a compact atomic clock comparable to a hydrogen maser.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.435603DOI Listing

Publication Analysis

Top Keywords

optical standard
12
high-performance compact
8
compact optical
8
optical frequency
8
optical
6
standard
4
standard describe
4
describe high-performance
4
frequency standard
4
standard based
4

Similar Publications

Human performance in psychophysical detection and discrimination tasks is limited by inner noise. It is unclear to what extent this inner noise arises from early noise (e.g.

View Article and Find Full Text PDF

Context: The two-dimensional graphene/MoTe heterostructure holds extensive potential applications in optoelectronic devices, sensors, and catalysts. To expand its optical applications, this study systematically investigates the adsorption stability of metal atoms (Au, Pt, Pd, and Fe) on the graphene/MoTe and their influence on its optoelectronic properties employing first-principles methods. The findings indicate that after the adsorption of Au and Pd, the structure retains its direct bandgap properties, while the adsorption of Pt and Fe exhibits indirect bandgap characteristics.

View Article and Find Full Text PDF

When used clinically, psychedelics may appear unusual or even unique when compared to more familiar or long-standing medical interventions, prompting some to suggest that the ethical issues raised may likewise be exceptional. If that is correct, then perhaps psychedelics should be treated differently from other medical substances: for example, by being subjected to different ethical or evidentiary standards. Alternatively, it may be that psychedelics have more in common with various existing medical interventions than first meets the eye.

View Article and Find Full Text PDF

Safety and Efficacy of Long-term Use of Infliximab in Severe Juvenile Dermatomyositis - 12 Years of Follow-up.

Acta Dermatovenerol Croat

November 2024

Prof. Marija Jelušić, MD, PhD, Department of Paediatrics, University of Zagreb, School of Medicine, Division of Clinical Immunology, Rheumatology and Allergology, Centre of Reference for Paediatric and Adolescent Rheumatology of Ministry of Health of the Republic Croatia, University Hospital Centre Zagreb, Kispaticeva 12, 10 000 Zagreb, Croatia;

Juvenile dermatomyositis with emphasized vasculopathy is rare, but the most severe form of the disease, with a poor prognosis with relapsing and chronic course or, in some cases, lethal outcome. We present a case of a 19-year-old Caucasian female, who developed severe acute juvenile dermatomyositis with emphasized multisystem vasculopathy, including retinal vasculopathy and maculopathy (cotton-wool spots, retinal hemorrhages, macular edema) at the age of 8. Due to no response to standard treatment protocols and rapid worsening of clinical symptoms and laboratory findings, a TNF inhibitor (infliximab) was introduced after the third week of treatment resulting in complete normalisation of muscle enzyme levels and complete resolution of eye changes within the next 2 weeks with a gradual general recovery.

View Article and Find Full Text PDF

This review explores recent technological advances in intraoperative imaging during retinal disease surgeries, focusing on their applicability in clinical practice and impact on surgical outcomes. A literature search identified studies discussing new imaging technologies, their advantages over conventional methods, relevant case studies, and literature reviews. Exclusion criteria included studies unrelated to retinal diseases, imaging technologies not suitable for intraoperative use, outdated articles, and nonscientific reports.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!