Introduction: Orthodontists have been using clear aligners to treat malocclusions, and one potential effect of treatment with orthodontic aligners is the intrusion and/or resists extrusion of the posterior teeth. This "bite-block effect" is primarily anecdotal due to the frequent occurrence of posterior open bites in patients after clear aligner therapy.

Objective: The purpose of this study was to compare changes promoted by clear aligners and traditional fixed appliances in cephalometric measurements of the vertical dimension and molar position in adult patients with Class I malocclusion treated with non-extraction.

Methods: Pre- and post-treatment lateral cephalometric radiographs of adult patients treated with either clear aligners (n=44) or traditional fixed appliances (n=22) were selected for retrospective analysis. Eight interval measurements and one nominal measurement were evaluated: anterior overbite (OB), mandibular plane angle related to cranial base (SN_MP) and related to Frankfort (FMA), lower molar height (L6H) and upper molar height (U6H), palatal plane to mandibular plane angle (PP_MP), lower facial height (LFH), total facial height (TFH), and posterior open bite (Posterior_OB). A single evaluator traced all cephalographs, and changes in select measures of the vertical dimension were compared within and between groups.

Results: OB decreased (1.15 mm) and L6H increased (0.63 mm) in the traditional fixed appliance group. Mandibular plane angles (related to cranial base and to Frankfort) increased (0.43° and 0.53°, respectively) in the clear aligner group, but just FMA showed significant difference between groups (difference of 0.53°). LFH and TFH increased (ranging from 0.52 mm to 0.80 mm) in both groups, with no differences between treatment modality. Presence of visible posterior open bite significantly increased over the course of treatment. OB, FMA and L6H exhibited an interaction between treatment stage (pre- and post-treatment) and modality (clear aligner therapy and traditional fixed appliances), but no interaction among these three variables was found.

Conclusions: The evidence does not support the theory that clear aligner therapy produces better vertical dimension control than traditional fixed appliances. Traditional fixed appliance therapy slightly extruded the lower molar, and clear aligner therapy produced a slightly mandibular backward rotation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8439186PMC
http://dx.doi.org/10.1590/2177-6709.26.4.e2119360.oarDOI Listing

Publication Analysis

Top Keywords

traditional fixed
28
fixed appliances
20
clear aligner
20
vertical dimension
16
clear aligners
16
posterior open
12
mandibular plane
12
aligner therapy
12
clear
9
dimension molar
8

Similar Publications

Current approaches for classifying biosensor data in diagnostics rely on fixed decision thresholds based on receiver operating characteristic (ROC) curves, which can be limited in accuracy for complex and variable signals. To address these limitations, we developed a framework that facilitates the application of machine learning (ML) to diagnostic data for the binary classification of clinical samples, when using real-time electrochemical measurements. The framework was applied to a real-time multimeric aptamer assay (RT-MAp) that captures single-frequency (12.

View Article and Find Full Text PDF

Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.

View Article and Find Full Text PDF

Background: Arthroplasty is the standard treatment for end-stage haemophilic knee arthritis; however, the choice between single knee arthroplasty (SKA) and bilateral knee arthroplasty (BKA) in a single operation remains controversial due to the risks specific to haemophiliacs.

Methods: Two independent researchers conducted searches across CNKI, CBM, Wanfang, PubMed, Cochrane Library, Embase, and Web of Science, with the last search performed on 15 October 2024. Study results include joint function, complication and various cost.

View Article and Find Full Text PDF

Facilitated Channeling of Fixed Carbon and Energy into Chemicals in Artificial Phototrophic Communities.

J Am Chem Soc

January 2025

State Key Laboratory of Microbial Metabolism, Joint International Research Laboratory of Metabolic & Developmental Sciences, School of Life Sciences & Biotechnology, and Zhangjiang Institute for Advanced Study, Shanghai Jiao Tong University, Shanghai, 200240, China.

Light-driven CO biovalorization offers a promising route for coupling carbon mitigation with petrochemical replacement. Synthetic phototrophic communities that mimic lichens can reduce the metabolic burden with improved CO utilization. However, inefficient channeling of carbon and energy between species seriously hinders the collaborative CO-to-molecule route.

View Article and Find Full Text PDF

MITIGATING OVER-SATURATED FLUORESCENCE IMAGES THROUGH A SEMI-SUPERVISED GENERATIVE ADVERSARIAL NETWORK.

Proc IEEE Int Symp Biomed Imaging

May 2024

Department of Electrical and Computer Engineering, Nashville, TN, USA.

Multiplex immunofluorescence (MxIF) imaging is a critical tool in biomedical research, offering detailed insights into cell composition and spatial context. As an example, DAPI staining identifies cell nuclei, while CD20 staining helps segment cell membranes in MxIF. However, a persistent challenge in MxIF is saturation artifacts, which hinder single-cell level analysis in areas with over-saturated pixels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!