Sudden cardiac accident (SCA) during a marathon is a concern due to the popularity of the sport. Preventive strategies, such as cardiac screening and deployment of automated external defibrillators have controversial cost-effectiveness. We investigated the feasibility of use of a new electrocardiography (ECG) sensor-embedded fabric wear (SFW) during a marathon as a novel preventive strategy against SCA. Twenty healthy volunteers participated in a full marathon race. They were equipped with a SFW hitoe® with a transmitter connected via Bluetooth to a standard smartphone for continuous ECG recording. All data were stored in a smartphone and used to analyze the data acquisition rate. The adequate data acquisition rate was > 90% in 13, 30-90% in 3, and < 10% in 4 runners. All of 4 runners with poorly recorded data were female. Inadequate data acquisition was significantly associated with the early phase of the race compared with the mid phase (P = 0.007). Except for 3 runners with poor heart rate data, automated software calculation was significantly associated with manual analysis for both the mean (P < 0.001) and maximum (P = 0.014) heart rate. We tested the feasibility of continuously recording cardiac data during a marathon using a new ECG sensor-embedded wearable device. Although data from 65% of runners were adequately recorded, female runners and the early phase of the race tended to have poor data acquisition. Further improvements in device ergonomics and software are necessary to improve ability to detect abnormal ECGs that may precede SCA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8438904PMC
http://dx.doi.org/10.1007/s00380-021-01939-3DOI Listing

Publication Analysis

Top Keywords

sensor-embedded fabric
8
fabric wear
8
full marathon
8
data acquisition
8
acquisition rate
8
initial evaluation
4
evaluation novel
4
novel electrocardiography
4
electrocardiography sensor-embedded
4
wear full
4

Similar Publications

The advent of bionic skin sensors represents a significant leap forward in the realm of wearable health monitoring technologies. Existing bionic skin technologies face several limitations, including complex and expensive manufacturing processes, low wearing comfort, and challenges in achieving comfortable real-time health monitoring. These shortcomings hinder the widespread adoption and practical utility of bionic skin in various applications.

View Article and Find Full Text PDF

Design and Fabrication of a Fiber Bragg Grating Shape Sensor for Shape Reconstruction of a Continuum Manipulator.

IEEE Sens J

June 2023

Department of Orthopedic Surgery, the Department of Mechanical Engineering, the Department of Computer Science, and the Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218 USA.

Article Synopsis
  • Continuum dexterous manipulators (CDMs) are highly maneuverable tools ideal for tasks in tight spaces, such as minimally invasive surgery, but controlling their shape in real-time during bending is challenging.
  • A new design featuring a large deflection fiber Bragg grating (FBG) shape sensor embedded in CDMs has been created to enhance shape-sensing capabilities using multiple fibers and nodes.
  • Experimental results showed strong accuracy in shape reconstruction and tracking, indicating the FBG sensor's effectiveness for practical applications in orthopedic surgery.
View Article and Find Full Text PDF

Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor.

ACS Omega

February 2024

CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India.

In the present global context, continuous blood pressure (BP) monitoring is paramount in addressing the global mortality rates attributed to hypertension. Achieving precise insights into the human cardiovascular system necessitates accurate measurement of BP, and the accuracy depends on the faithful recording of oscillations or pulsations. This task ultimately depends on the caliber of the pressure sensor embedded in the BP device.

View Article and Find Full Text PDF

This paper proposes a novel phase-resolved partial discharge (PRPD) sensor embedded in a MV-class bushing for high-accuracy insulation analysis. The design, fabrication, and evaluation of a PRPD sensor embedded in a MV-class bushing aimed to achieve the detection of partial discharge (PD) pulses that are phase-synchronized with the applied primary HV signal. A prototype PRPD sensor was composed of a flexible printed circuit board (PCB) with dual-sensing electrodes, utilizing a capacitive voltage divider (CVD) for voltage measurement, the D-dot principle for PD detection, and a signal transducer with passive elements.

View Article and Find Full Text PDF

Flexible Iron-On Sensor Embedded in Smart Sock for Gait Event Detection.

ACS Appl Mater Interfaces

January 2024

School of Engineering and Built Environment, Griffith University, Gold Coast 4222, QLD, Australia.

Portable and wearable electronics for biomechanical data collection have become a growing part of everyday life. As smart technology improves and integrates into our lives, some devices remain ineffective, expensive, or difficult to access. We propose a washable iron-on textile pressure sensor for biometric data acquisition.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!