Purpose: Dynamic text presentation methods may improve reading ability in patients with central vision loss (CVL) by eliminating the need for accurate eye movements. We compared rapid serial visual presentation (RSVP) and horizontal scrolling text presentation (scrolling) on reading rate and reading acuity in CVL observers and normally-sighted controls with simulated CVL (simCVL).

Methods: CVL observers' (n = 11) central scotomas and preferred retinal loci (PRL) for each eye were determined with MAIA microperimetry and fixation analysis. SimCVL controls (n = 16) used 4° inferior eccentric viewing, enforced with an Eyelink eye-tracker. Observers read aloud 4-word phrases randomly drawn from the MNREAD sentences. Six font sizes (0.50-1.30 logMAR) were tested with the better near acuity eye and both eyes of CVL observers. Three font sizes (0.50-1.00 logMAR) were tested binocularly in simCVL controls. Text presentation duration of each word for RSVP or drift speed for scrolling was varied to determine reading rate, defined as 50% of words read correctly. In a subset of CVL observers (n = 7), relationships between PRL eccentricity, reading threshold and rate were explored.

Results: SimCVL controls demonstrated significantly faster reading rates for RSVP than scrolling text (p < 0.0001), and there was a significant main effect of font size (p < 0.0001). CVL patients demonstrated no significant differences in binocular reading rate between font sizes (p = 0.12) and text presentation (p = 0.25). Similar results were seen under monocular conditions. Reading acuity for RSVP and scrolling worsened with increasing PRL eccentricity (μ = 4.5°, p = 0.07). RSVP reading rate decreased significantly with increasing eccentricity (p = 0.02).

Conclusions: Consistent with previous work, reading acuity worsened with increasing PRL eccentricity. RSVP and scrolling text presentations significantly affected reading rate in simCVL, but not in CVL observers, suggesting that simCVL results may not generalise to pathological CVL.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8808432PMC
http://dx.doi.org/10.1111/opo.12881DOI Listing

Publication Analysis

Top Keywords

text presentation
12
cvl observers
12
simcvl controls
12
dynamic text
8
central vision
8
vision loss
8
scrolling text
8
reading rate
8
font sizes
8
reading
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!