Objective: There is still a lack in precise postoperative evaluation of the cochlea because of strong artifacts. This study aimed to improve accuracy of postoperative two-turn (2TL) and cochlear duct length (CDL) measurements by applying flat-panel volume computed tomography (fpVCT), secondary reconstruction (fpVCT) and three-dimensional curved multiplanar reconstruction.
Methods: First, 10 temporal bone specimens with or without electrode were measured in multi-slice computed tomography (MSCT), fpVCT and fpVCT and compared to high-resolution micro-CT scans. Later, pre- and postoperative scans of 10 patients were analyzed in a clinical setting.
Results: Concerning 2TL, no statistically significant difference was observed between implanted fpVCT and nonimplanted micro-CT in 10 temporal bone specimens. In contrast, there was a significant discrepancy for CDL (difference: -0.7 mm, P = 0.004). Nevertheless, there were no clinically unacceptable errors (±1.5 mm). These results could be confirmed in a clinical setting. Using fpVCT, CDL was slightly underestimated postoperatively (difference: -0.5 mm, P = 0.002) but without any clinically unacceptable errors.
Conclusion: fpVCT can be successfully applied for a precise measurement of the cochlear lengths pre- and postoperatively. However, users must be aware of a slight systematic underestimation of CDL postoperatively. These results may help to refine electrode selection and frequency mapping.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/14670100.2021.1973208 | DOI Listing |
Med Phys
January 2025
Department of Oncology, The Affiliated Hospital of Southwest Medical University, Luzhou, China.
Background: Kidney tumors, common in the urinary system, have widely varying survival rates post-surgery. Current prognostic methods rely on invasive biopsies, highlighting the need for non-invasive, accurate prediction models to assist in clinical decision-making.
Purpose: This study aimed to construct a K-means clustering algorithm enhanced by Transformer-based feature transformation to predict the overall survival rate of patients after kidney tumor resection and provide an interpretability analysis of the model to assist in clinical decision-making.
Oral Radiol
January 2025
Faculty of Dentistry, Department of Oral and Maxillofacial Radiology, Istanbul University, Istanbul, Turkey.
Objectives: This study evaluates the potential of pulp volume/total tooth-volume measurements of canine teeth in relation to chronologic age in patients with cleft lip and palate (CLP). The significance of this study lies in its exploration of the usability of these measurements for age determination in CLP patients, providing a novel perspective to the existing literature.
Methods: Cone beam computed tomography images of 33 patients (16 females, 17 males) with unilateral CLP aged 14-45 years and 33 age- and sex-matched healthy individuals (16 females, 17 males) were retrospectively evaluated.
J Imaging Inform Med
January 2025
Department of Orthopedic Surgery, Arrowhead Regional Medical Center, Colton, CA, USA.
Rib pathology is uniquely difficult and time-consuming for radiologists to diagnose. AI can reduce radiologist workload and serve as a tool to improve accurate diagnosis. To date, no reviews have been performed synthesizing identification of rib fracture data on AI and its diagnostic performance on X-ray and CT scans of rib fractures and its comparison to physicians.
View Article and Find Full Text PDFJ Imaging Inform Med
January 2025
Leiden University Medical Center (LUMC), Leiden, the Netherlands.
Rising computed tomography (CT) workloads require more efficient image interpretation methods. Digitally reconstructed radiographs (DRRs), generated from CT data, may enhance workflow efficiency by enabling faster radiological assessments. Various techniques exist for generating DRRs.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
January 2025
Department of Radiology, Massachusetts General Hospital, Boston, MA, USA.
The use of conventional contrast agents in computed tomography (CT) and magnetic resonance (MR) imaging is often limited in patients with chronic kidney disease (CKD) due to potential nephrotoxicity. Ferumoxytol, originally developed for iron supplementation, has emerged as a promising alternative MR contrast agent that is safer for patients with CKD. This study aims to present our center's experience with ferumoxytol as a contrast agent in CKD patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!