A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surface analysis of dental caries using a wireless pH sensor and Raman spectroscopy for chairside diagnosis. | LitMetric

A chairside tool for quantitative analysis of dental caries would improve clinical dental inspections. The wireless caries sensing tool with dental-explorer size has been developed comparing two sensing methods, Raman reading and pH reading for evaluating dental caries. The Raman spectra at 575 cm and 960 cm for in inorganic compounds, as well as 1450 cm and 2940 cm for organic compounds reinforced and supported the pH results. An Iridium/Iridium oxide (Ir/IrOx) pH sensing probe and wireless pH sensor (comprising an ESP8266 ESP-01 wireless module and ADS1115 analog digital converter) has been developed to quantitatively evaluate dental caries. All the operations of the wireless pH sensor were performed with a developed LabVIEW-based real-time data monitoring program. The slope and the linear fitting regression value (R) of the wireless pH sensor using seven standards were -54.9 mV/pH and 0.999, respectively, showing high accuracy and stability for the pH measurements. The pH on the dental caries surface was measured with the wireless pH sensor, and the pH mapping results in the non-caries and caries areas were 6.9 and 5.7, respectively. The developed wireless pH sensor would be useful to understand the condition of dental caries and support dentists' inspection to remove only the caries part while keeping the non-caries structure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2021.122718DOI Listing

Publication Analysis

Top Keywords

dental caries
24
wireless sensor
24
caries
9
analysis dental
8
wireless
8
dental
7
sensor
6
surface analysis
4
caries wireless
4
sensor raman
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!