A perturbed postural balance test can be used to investigate balance control under mechanical disturbances. The test is typically performed using purpose-built movable force plates. As instrumented treadmills become increasingly common in biomechanics laboratories and in clinical settings, these devices could be potentially used to assess and train balance control. The purpose of the study was to investigate how an instrumented treadmill applies to perturbed postural balance test. This was investigated by assessing the precision and reliability of the treadmill belt movement and the test-retest reliability of perturbed postural balance test over 5 days. Postural balance variables were calculated from the center of pressure trajectory and included peak displacement, time to peak displacement, and recovery displacement. Additionally, the study investigated short-term learning effects over the 5 days. Eight healthy participants (aged 24-43 years) were assessed for 5 consecutive days with four different perturbation protocols. Center of pressure (COP) data were collected using the force plates of the treadmill while participant and belt movements were measured with an optical motion capture system. The results show that the treadmill can reliably deliver the intended perturbations with <1% deviation in total displacement and with minimal variability between days and participants (typical errors 0.06-2.71%). However, the treadmill was not able to reach the programmed 4 m/s acceleration, reaching only about 75% of it. Test-retest reliability of the selected postural balance variables ranged from poor to good (ICC 0.156-0.752) with typical errors between 4.3 and 28.2%. Learning effects were detected based on linear or quadratic trends ( < 0.05) in peak displacement of the slow forward and fast backward protocols and in time to peak displacement in slow and fast backward protocols. The participants altered the initial location of the COP relative to the foot depending on the direction of the perturbation. In conclusion, the precision and accuracy of belt movement were found to be excellent. Test-retest reliability of the balance test utilizing an instrumented treadmill ranged from poor to good which is, in line with previous investigations using purpose-built devices for perturbed postural balance assessment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8429482PMC
http://dx.doi.org/10.3389/fspor.2021.688993DOI Listing

Publication Analysis

Top Keywords

postural balance
20
perturbed postural
16
balance test
16
balance
8
instrumented treadmill
8
belt movement
8
movement test-retest
8
test-retest reliability
8
balance control
8
force plates
8

Similar Publications

Neuromuscular Strategies in Dominant and Non-Dominant Legs in Dancers During Dynamic Balance Tasks.

J Dance Med Sci

January 2025

Frontier Research Institute of Convergence Sports Science, College of Educational Sciences, Yonsei University, Seoul, Korea.

Ballet-based dance training emphasizes the equal development of both legs. However, dancers often perceive differences between their legs during balance or landing. There still needs to be more consensus on the functional difference between dominant (D) and non-dominant legs (ND).

View Article and Find Full Text PDF

Cerebral palsy (CP) manifests with abnormal posture and impaired selective motor control, notably affecting trunk control and dynamic balance coordination, leading to inadequate postural control. Previous research has indicated the benefits of pulsed electromagnetic field (PEMF) therapy for various musculoskeletal and neurological conditions. Therefore, we conducted a randomized pilot study to assess the feasibility of our preliminary research design and examine the effect of the PEMF treatment among children with CP.

View Article and Find Full Text PDF

Background: Semi-aquatic mammals represent a transitional phase in the evolutionary spectrum between terrestrial and aquatic mammals. The sense of balance is crucial for mammalian locomotion, and in semi-aquatic mammals, the structural foundation of this sense (the vestibular system) shows distinct morphological adaptations to both aquatic and terrestrial environments compared to their terrestrial counterparts. Despite this, the precise molecular mechanisms driving these adaptations remain elusive.

View Article and Find Full Text PDF

Objective: To compare fall risk scores of hearing aids embedded with inertial measurement units (IMU-HAs) and powered by artificial intelligence (AI) algorithms with scores by trained observers.

Study Design: Prospective, double-blinded, observational study of fall risk scores between trained observers and those of IMU-HAs.

Setting: Tertiary referral center.

View Article and Find Full Text PDF

Effects of kinesio taping on lower limb biomechanical characteristics during dynamic postural control tasks in individuals with chronic ankle instability.

PLoS One

January 2025

Key Laboratory of Sports Engineering of General Administration of Sport of China, Wuhan Sports University, Wuhan, Hubei Province, China.

Purpose: Previous studies have demonstrated significant biomechanical differences between individuals with chronic ankle instability (CAI) and healthy controls during the Y-balance test. This study aimed to examine the effects of kinesio taping (KT) on lower limb biomechanical characteristics during the Y-balance anterior reach task in individuals with CAI.

Methods: A total of 30 participants were recruited, comprising 15 individuals with CAI and 15 healthy controls.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!