Unlabelled: We assessed two electronic search tools that screen medical records for documented fractures. Both programs reliably identified patients with any fracture but missed individuals with minimal trauma fracture to different degrees. A hybrid tool combining the methodology of both tools is likely to improve the identification of those with osteoporosis.
Purpose: Most patients who suffer a minimal trauma fracture remain undiagnosed, placing them at high risk of refracture. Case finding can be improved by electronic search tools that screen medical records for documented fractures. Here, we assessed the efficacy of two new programs, AES and XRAIT, in identifying patients with minimal trauma fracture.
Methods: Each tool was applied to search the electronic medical record and/or radiology reports at two tertiary hospitals in Sydney, Australia, from 1 July to 31 December 2018. Samples of the extracted reports were then manually reviewed to determine the sensitivity of each program in detecting minimal trauma fractures.
Results: At the two centers, AES detected 872 and 1364 cases, whereas XRAIT identified 1414 and 2180 patients with fractures, respectively. The true positive rate for "any fracture" was similar for both instruments (77-88%). However, the ability to detect "minimal trauma fractures" differed between programs and centers (53-75% accuracy), with each tool identifying separate subsets of patients. Concordance between both tools was less than half of the combined total number of minimal trauma fractures (43-45%). Considering the total number of minimal trauma fractures detected by both tools combined, AES correctly identified 52-55% of cases while XRAIT identified 88-93% of cases.
Conclusion: Both programs reliably identified patients with any fracture but missed individuals with minimal trauma fracture to different degrees. Hybrid tools combining the methodology of XRAIT and AES are likely to improve the identification of patients who require investigation and treatment for osteoporosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00198-021-06105-z | DOI Listing |
Proximal humeral fractures (PHF), ranking as the third most common osteoporotic fractures, pose a significant challenge in management. With a rising incidence in an aging population, controversy surrounds surgical versus nonoperative treatments, particularly for displaced 3- and 4-part fractures in older patients. Locking plates (LP) and proximal intramedullary nails (PHN) are primary choices for surgical intervention, but both methods entail complications.
View Article and Find Full Text PDFActa Orthop Belg
September 2024
The aim of this paper is to identify if there is a difference in length of stay following hip fractures when using rehabilitation beds. Prospective data was collected on all hip fracture admissions in patients over 50 years from May 2016 to February 2018 from ISD NHS Scotland to identify length of stay. It was found that patients discharged home via rehabilitation wards were less likely to have returned to their own home by 30 days post admission and were also significantly more likely to stay in hospital for 40 days or more when compared to patients discharged directly home.
View Article and Find Full Text PDFArch Bone Jt Surg
January 2024
Department of Epidemiology, School of Public Health, Iran University of Medical Sciences, Tehran, Iran.
Objectives: This study aimed to introduce a new arthroscopic method for reconstructing the popliteus tendon (PT). This minimally invasive technique is performed through the posterolateral corner (PLC) of the knee, which can reconstruct the posterolateral rotary instability (PLRI) of the knee.
Methods: Thirty-nine patients (8 females, 31 males) with PLC injury and normal knee alignment underwent arthroscopic PT reconstruction.
J Orthop
August 2025
Department of Orthopaedic Surgery, Oita University Hospital, Japan.
Background: This study examines the relationship between the anterior offset of the tibial intramedullary nail (TIN) entry point and the tibial shaft axis to enhance the fit and alignment of TINs, using transparent 3D-CT in an accurate lateral view to minimize rotational artifacts.
Methods: Data were collected from 100 adult patients undergoing tibial CT scans. Measurements included the anterior offset from the tibial axis to the entry point, tibial tubercle offset, tibial plateau length, posterior slope, tibial length, isthmus diameter, and the isthmus-to-tibial length ratio.
Aesthetic Plast Surg
January 2025
Department of Wound Repair, The Second Affiliated Hospital of Hunan University of Chinese Medicine, Changsha City, Hunan Province, P.R. China.
Background: Upper eyelid ptosis is a common aesthetic concern among Asian patients, resulting in a tired and drowsy appearance that affects their attractiveness. The levator advancement technique is widely used for ptosis correction; however, achieving precise results remains challenging.
Objectives: This study introduces a modified approach to improve the accuracy of levator aponeurosis advancement by focusing on precise measurements and anterior displacement within a defined corneal range.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!