Significance: Optometric educators are constantly looking for learning and teaching approaches to improve clinical skills training. In addition, the COVID-19 pandemic has made educators scrutinize the time allocated to face-to-face teaching and practice. Simulation learning is an option, but its use must first be evaluated against traditional learning methods.
Purpose: The purpose of this study was to compare the training of binocular indirect ophthalmoscopy skills achieved by students and optometrists through deliberate practice on the Eyesi Indirect Ophthalmoscope simulator with deliberate practice using a peer.
Methods: Students and optometrists were randomly allocated to practice on either the simulator or a peer. Binocular indirect ophthalmoscopy performance was assessed using a peer and the simulator as the patients at different time points. Knowledge and confidence were examined before and following all practice sessions using a quiz and survey.
Results: Significant improvements in binocular indirect ophthalmoscopy performance using either a peer or the simulator as the patient for assessment were seen after 8 hours of student practice (P < .001) and after a half-hour practice time for optometrists (P < .001). There was no significant difference in performance overall between those practicing on a simulator and those practicing on a peer (P > .05). Confidence in ability to perform the technique was lower for students who had practiced on the simulator.
Conclusions: The simulator has similar efficacy to peer practice for teaching binocular indirect ophthalmoscopy to students and maintenance of this clinical skill for optometrists. Simulation does not replace the need for peer practice but may be a useful adjunct reducing the face-to-face hours required. These findings present a need for further research regarding diverse applications of the Eyesi Indirect Ophthalmoscope simulator in the curriculum for training optometry students and as a continuing professional development offering for optometrists, given the short exposure duration required to observe a significant improvement in skill.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/OPX.0000000000001799 | DOI Listing |
Eye (Lond)
November 2024
Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.
This systematic review and network meta-analysis (NMA) focuses on comparing monovision and bilateral multifocal lenses (bMFIOL) implantation methods in treating presbyopia, a common age-related condition often seen in post-cataract surgery patients. This review focuses on evaluating the efficacy, user satisfaction and limitations of these two approaches through direct or indirect comparison. A comprehensive search was conducted in Medline, Embase, and Cochrane library, considering studies up to 15 July 2022, with direct or indirect comparisons between any monovision and bMFIOL implantation with bilateral cataract surgery.
View Article and Find Full Text PDFOpen Res Eur
August 2024
ACRI-ST, Grasse, 06130, France.
Background: Identifying stars belonging to different classes is vital in order to build up statistical samples of different phases and pathways of stellar evolution. In the era of surveys covering billions of stars, an automated method of identifying these classes becomes necessary.
Methods: Many classes of stars are identified based on their emitted spectra.
Pediatr Rep
July 2024
Department of Medicine and Surgery, Section of Ophthalmology, University of Perugia, S. Maria Della Misericordia Hospital, 06129 Perugia, Italy.
Background: Fluorescein angiography (FA) has been a pivotal tool for studying the pathophysiology of retinopathy of prematurity (ROP) in vivo. We examined the course of ROP using FA to assess the predictive value of angiographic features.
Methods: This is an observational retrospective cohort study of eyes screened for ROP with a binocular indirect ophthalmoscope and FA.
Dent Res J (Isfahan)
July 2024
Department of Prosthodontics, Goa Dental College and Hospital, Bambolim, Goa, India.
Background: There is limited literature available comparing the accuracy of intraradicular impressions made with a novel hybrid impression material using the indirect and direct technique at three different locations.
Materials And Methods: For this comparative analysis, postspace was prepared in 15 recently extracted teeth and impressions made with vinyl polysiloxane, polyether (PE), vinyl polyether silicone (VPES), and pattern resin. Postpatterns obtained were re-seated on the teeth and longitudinally sectioned.
Rom J Ophthalmol
July 2024
Department of Behavioural Medicine, Lagos State University College of Medicine, Lagos State, Nigeria.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!