Application of multi-pinhole collimator in pinhole-based SPECT increases detection sensitivity. The presence of multiplexing in projection images due to the usage of multiple pinholes can further improve the sensitivity at the cost of adding data ambiguity. We are developing a next-generation adaptive brain-dedicated SPECT system -AdaptiSPECT-C. The AdaptiSPECT-C can adapt the multiplexing level and system sensitivity using adaptable pinhole modules. In this study, we investigated the performance of 4 data acquisition schemes with different multiplexing levels and sensitivities on cerebral SPECT imaging. Schemes #1, #2, and #3 have <1%, 67%, and 31% overall multiplexing, respectively, while the 4th scheme without multiplexing is considered as ground truth. The ground-truth and schemes #1-3 have 1.0, 1.7, 5.1, and 4.0 times higher sensitivity, respectively, compared to a dual-headed parallel-hole SPECT system at matched spatial resolution. A customized XCAT brain perfusion digital phantom emulating the distribution of I-123 N-isopropyl iodoamphetamine (IMP) in a 99th percentile size male was used for simulations. Data acquisition for each scheme was performed at two count levels (low-count and high-count relative to the recommended clinical count level). The normalized root-mean-square error (NRMSE) for schemes #1, #2, and #3 with the low-count (high-count) scenario showed 11%, 4%, and 5% (10%, 5%, and 6%) deviation, respectively, from that of the multiplex-free ground truth. For both the low-count and high-count scenarios, scheme #1 resulted in the least accurate activity ratio (AR) for almost all the analyzed gray-matter brain regions. Further schemes #2 or #3 led to the most accurate AR values with both low-count and high-count scenarios for all the analyzed gray-matter regions. It was thus observed that even with this large head size which leads to significant multiplexing levels, the higher sensitivity from multiplexing could to some extent mitigate the data ambiguity and be translated into reconstructed images of higher quality.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8690572 | PMC |
http://dx.doi.org/10.1088/2057-1976/ac25c3 | DOI Listing |
J Neuroimaging
January 2025
Neurobiology Research Unit, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark.
Background And Purpose: This study aims to investigate the longitudinal changes in translocator protein (TSPO) following stroke in different brain regions and potential associations with chronic brain infarction.
Methods: Twelve patients underwent SPECT using the TSPO tracer 6-Chloro-2-(4'-123I-Iodophenyl)-3-(N,N-Diethyl)-Imidazo[1,2-a]Pyridine-3-Acetamide, as well as structural MRI, at 10, 41, and 128 days (median) after ischemic infarction in the middle cerebral artery. TSPO expression was measured in lesional (MRI lesion and SPECT lesion), connected (pons and ipsilesional thalamus), and nonconnected (ipsilesional cerebellum and contralesional occipital cortex) regions.
Clin Nucl Med
January 2025
From the Department of Nuclear Medicine, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
A 7-year-old boy with high-risk neuroblastoma underwent 123I-MIBG SPECT/CT to evaluate the therapy response. The scan revealed abnormal 123I-MIBG uptake in the left basal ganglion, indicating the possibility of brain metastasis. Subsequent contrast-enhanced brain MRI, however, did not show any abnormal signal intensity in the left basal ganglion.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
January 2025
Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, 6-1 Kishibe-Shimmachi, Suita, Osaka, 564-8565, Japan.
Background: Non-response to cardiac resynchronization therapy (CRT) is an important issue in the treatment of heart failure with reduced ejection fraction (HFrEF) and non-left bundle branch block (LBBB). Electrocardiogram-gated myocardial perfusion single-photon emission computed tomography imaging (G-MPI SPECT) is typically used to assess left ventricular (LV) dyssynchrony. This study aimed to determine whether G-MPI parameters are associated with non-responsiveness to CRT.
View Article and Find Full Text PDFRadiographics
January 2025
From the Department of Radiology, University of Cincinnati Medical Center, 3188 Bellevue Ave, Cincinnati, OH 45219 (A.S., A.T.T., B.W.M., L.L.W., J.L.S.); and Department of Radiology, Cincinnati Children's Hospital and Medical Center, Cincinnati, OH (A.T.T.).
Approximately one-third of patients with focal epilepsy have medically refractory focal epilepsy (MRFE), which significantly impacts their quality of life. Once a seizure focus is identified and determined to be in the noneloquent cortex, it can be surgically resected with the goal of freedom from seizures and minimal neurocognitive deficit. During noninvasive (phase I) presurgical planning, functional (nuclear) imaging and structural imaging are complementary in the accurate localization of the epileptogenic zone (EZ).
View Article and Find Full Text PDFAsia Ocean J Nucl Med Biol
January 2025
Department of Radiological Technology, Faculty of Medical Technology, Tokyo, Japan.
Objectives: Brain perfusion single-photon emission computed tomography (SPECT) image quality varies depending on SPECT systems. This study aimed to evaluate the relationship between physical parameters and visual analysis for assessment of the brain SPECT image quality. We conducted our phantom study under various conditions in a multi-center and multi-vendor study.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!