Purpose: To assess the precision of a new spectral-domain optical coherence tomographer (SD-OCT)/Placido topographer (MS-39; CSO) and its comparison with a swept-source OCT (SS-OCT) biometer (Argos; Movu, Inc) in patients with cataract.

Methods: Fifty-three right eyes from 53 patients were examined by two experienced operators three times using both devices randomly. Employing the within-subject standard deviation (S), test-retest variability, coefficient of variation, and intraclass correlation coefficient to evaluate intraoperator repeatability and interoperator reproducibility; the double-angle plots to analyze astigmatism; and Bland-Altman plots and 95% limits of agreement to verify the agreement between devices.

Results: The SD-OCT/Placido tomographer showed high precision, with coefficient of variation of 0.44% or less, intraclass correlation coefficient of 0.945 or greater for all parameters, test-retest variability of 4.21 µm or less for central corneal thickness (CCT), 0.03 mm or less for anterior chamber depth (ACD) and aqueous depth (AQD), and 0.25 diopters (D) or less for mean keratometry (Km), J, and J. The inter-device differences in Km, J, and J were statistically insignificant, whereas the remaining were statistically but not clinically significant. The 95% limits of agreement of CCT, ACD, AQD, Km, J, and J were -3.70 to 15.25 µm, -0.06 to 0.04 mm, -0.06 to 0.04 mm, -0.28 to 0.35 D, -0.27 to 0.26 D, and -0.27 to 0.21 D, respectively. The double-angle plot confirmed the high agreement in astigmatism.

Conclusions: For CCT, ACD, AQD, Km, and astigmatism measurements in patients with cataract, the new SD-OCT/Placido tomographer has excellent precision and high agreement with the Argos SS-OCT biometer, and can be used interchangeably. .

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20210610-02DOI Listing

Publication Analysis

Top Keywords

optical coherence
8
coherence tomographer
8
comparison swept-source
8
patients cataract
8
ss-oct biometer
8
test-retest variability
8
coefficient variation
8
intraclass correlation
8
correlation coefficient
8
95% limits
8

Similar Publications

Background: Patients with acute myocardial infarction and angiographically obstructive non-culprit lesions are at high risk for recurrent major adverse cardiac events (MACEs). However, it remains largely unknown whether events are due to stenosis severity or due to the underlying high-risk lesion morphology.

Methods: Between January 2017 and December 2021, 1312 patients with acute myocardial infarction underwent optical coherence tomography of all the 3 main epicardial arteries after successful percutaneous coronary intervention.

View Article and Find Full Text PDF

Myocardial bridging is a frequent anomaly of the heart in humans and other animals. A myocardial bridge is typically characterized by the systolic narrowing seen with traditional catheter angiography, but this abnormality is not by itself a sign of ischemia or the need for intervention. In particular, transient spontaneous angina must be corroborated by reproducible narrowing during acetylcholine testing; this narrowing occurs during resting conditions and is responsive to nitroglycerin administration.

View Article and Find Full Text PDF

Purpose: Systemic sclerosis (SSc) affects blood vessels, internal organs, and skin. In ophthalmology, SSc impacts the choroid. The choroidal vascularity index (CVI) measures the vascular component of the choroid and may serve as a biomarker for the disease staging and prognosis.

View Article and Find Full Text PDF

Diagnostic approach to limbal stem cell deficiency.

Front Ophthalmol (Lausanne)

January 2025

Department of Ophthalmology and Visual Science, University of Chicago, Chicago, IL, United States.

Limbal stem cell deficiency (LSCD) is an important cause of visual and ocular morbidity. Effective diagnosis and management require a thoughtful and comprehensive evaluation of the ocular surface. This review describes the pathogenesis, diagnosis, and grading of LSCD, as well as characteristic findings via slit lamp examination, confocal microscopy, anterior segment optical coherence tomography (AS-OCT), impression cytology, and OCT angiography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!