Birch ( Roth.) and beech ( L.) solid wood and plywood were overmolded with polyamide 6 (PA 6) and polypropylene (PP) to investigate their mechanical properties and interfacial adhesion. In the case of PA 6, maximum tensile shear strengths values of more than 8 to 9 MPa were obtained for birch and beech, respectively. The values are comparable to bond strengths of commercial joints bonded with formaldehyde-containing amino-plastics. Perpendicular to the wood elements, bond strength values of 3 MPa was achieved for PA 6. The penetration of the polymers into the wood structure results in a non-densified interphase and subsequent plastic deformation of the wood structure beyond the interphase. These compressed areas influenced the interfacial adhesion and mechanical interlocking. SEM and XPS analysis revealed different interpenetration behavior of the polymers into the wood structure, with chemical interaction confirmed only for wood and PA 6 but not PP.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8434067 | PMC |
http://dx.doi.org/10.3390/polym13172849 | DOI Listing |
Angew Chem Int Ed Engl
December 2024
Key Lab for Special Functional Materials of Ministry of Education, National & Local Joint Engineering Research Center for High-efficiency Display and Lighting Technology, School of Nanoscience and Materials Engineering, Collaborative Innovation Center of Nano Functional Materials and Applications, Henan University, Kaifeng, 475004, P. R. China.
Flexible perovskite solar cells (FPSCs) are a promising emerging photovoltaic technology, with certified power conversion efficiencies reaching 24.9 %. However, the frequent occurrence of grain fractures and interface delamination raises concerns about their ability to endure the mechanical stresses caused by temperature fluctuations.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
Soete Laboratory, Faculty of Engineering and Architecture, Ghent University, B-9052 Ghent, Belgium.
Epoxy resins have exhibited exceptional performance in engineering applications, particularly as a replacement for traditional mechanical joints in adhesive bonding. This study evaluates the suitability of two innovative adhesives, SikaPower-1511 and SikaPower-1548, in various graded configurations. The thermal curing behavior of the adhesives was analyzed using differential scanning calorimetry (DSC) and Fourier transform infrared spectroscopy (FTIR).
View Article and Find Full Text PDFPolymers (Basel)
December 2024
School of Biomedical Engineering and Imaging, Xianning Medical College, Hubei University of Science and Technology, Xianning 437100, China.
Powder-based hemostatic materials have offered unprecedented opportunities for the effective sealing and repair of irregularly shaped wounds and high-pressure, noncompressible arterial bleeding wounds caused by surgeries, traffic accidents, and wartime injuries. However, inadequate adhesion to bleeding wounds and poor hemostasis in biological tissues remains challenging. Herein, we report a self-gelling hemostatic powder based on polyacrylic acid/polyethyleneimine/polyethylene glycol (named PPG) for rapid hemostasis and effective antibacterial ability.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100124, China.
Filler defects and matrix crosslinking degree are the main factors affecting the interfacial adhesion properties of propellants. Improving adhesion can significantly enhance debonding resistance. In this study, all-atom molecular dynamics (MD) simulations are employed to investigate the interfacial adsorption behavior and mechanisms between ammonium perchlorate (AP) fillers and a poly(3,3-bis-azidomethyl oxetane)-tetrahydrofuran (PBT) matrix.
View Article and Find Full Text PDFBioengineering (Basel)
December 2024
Plastic, Reconstructive and Hand Surgery Service, Lausanne University Hospital, University of Lausanne, CH-1011 Lausanne, Switzerland.
The human skin is a remarkable organ capable of extensive regeneration, especially after severe injuries such as burns and related wounds. The de-epidermized dermis (DED) model has become a valuable in vitro tool for skin regeneration studies, particularly for testing the mechanism of action and the efficacy of clinical cutaneous cell therapies. To further improve the quality and robustness of these applications, our study focused on optimizing and standardizing DED tissue preparation and storage, enhancing its effectiveness for clinical testing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!