[New aspects in the diagnosis and treatment of the symptom of a lump in the throat].

Vestn Otorinolaringol

North Caucasus State Academy, Cherkessk, Russia.

Published: September 2021

A lump in the throat () is a form of paresthesia of the upper respiratory tract that impairs the quality of life of about 45% of people. This symptom is not pathognomonic for any disease. To improve the quality of diagnosis and treatment of patients with a complaint of a lump in the throat, a comprehensive examination and treatment of 47 patients aged 28 to 75 years were carried out, in which this complaint persisted despite the pathogenetic treatment. In the study, we used a video laryngoscope and a single-channel device for electrical stimulation. The results of the work showed that in more than 70% of the observed patients, the accommodation coefficient was reduced. This indicates a violation of the neuromuscular transmission of the larynx. By the end of treatment, in 68.1% of patients, the studied parameter was within its normal values. A comparative analysis of the degree of coma in the throat before and after treatment with the a single-channel device for electrical stimulation apparatus showed that by the end of treatment, all patients showed a decrease in the severity of the symptom, with 70.2% of patients reporting its absence. Conducted psychological testing revealed that in more than 60% of patients indicators of mental activity, tension and comfort were moderately changed. After a course of neuromuscular electrophonopedic stimulation, all examined patients showed positive dynamics in the form of restoration of mental activity, reduction of tension and increase of comfort.

Download full-text PDF

Source
http://dx.doi.org/10.17116/otorino20218604141DOI Listing

Publication Analysis

Top Keywords

treatment patients
12
diagnosis treatment
8
lump throat
8
patients
8
single-channel device
8
device electrical
8
electrical stimulation
8
mental activity
8
treatment
7
[new aspects
4

Similar Publications

Introduction: Wearables are electronic devices worn on the body to collect health data. These devices, like smartwatches and patches, use sensors to gather information on various health parameters. This review highlights current use and the potential benefit of wearable technology in patients with inflammatory bowel disease (IBD).

View Article and Find Full Text PDF

Introduction: Antibody-drug conjugates (ADCs) are a rapidly evolving class of anti-cancer drugs with a significant impact on management of hematological malignancies including diffuse large B-cell lymphoma (DLBCL). ADCs combine a cytotoxic drug (a.k.

View Article and Find Full Text PDF

Study Objectives: Deep brain stimulation (DBS) of the subthalamic nucleus (STN) may improve sleep dysfunction, a common non-motor symptom of Parkinson disease (PD). Improvement in motor symptoms correlates with DBS-suppressed local field potential (LFP) activity, particularly in the beta frequency (13 - 30 Hz). Although well-characterized in the short term, little is known about the innate progression of these oscillations across the sleep-wake cycle.

View Article and Find Full Text PDF

Beyond the Herald Patch: Exploring the Complex Landscape of Pityriasis Rosea.

Am J Clin Dermatol

January 2025

Dr. Phillip Frost Department of Dermatology and Cutaneous Surgery, University of Miami Miller School of Medicine, Miami, FL, 33136, USA.

Pityriasis rosea (PR) is a prevalent dermatological condition characterized by a distinctive herald patch, followed by secondary eruptions, often forming a "Christmas tree" pattern on the trunk. Despite its recognizable clinical presentation, the etiology of PR remains uncertain, with hypotheses pointing to both infectious and noninfectious origins. Human herpesviruses (HHV) 6 and 7 have been implicated, with evidence suggesting viral reactivation as a potential trigger.

View Article and Find Full Text PDF

Background: Continuous veno-venous hemodiafiltration (CVVHDF) is used in critically ill patients, but its impact on O₂ and CO₂ removal, as well as the accuracy of resting energy expenditure (REE) measurement using indirect calorimetry (IC) remains unclear. This study aims to evaluate the effects of CVVHDF on O₂ and CO₂ removal and the accuracy of REE measurement using IC in patients undergoing continuous renal replacement therapy.

Design: Prospective, observational, single-center study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!