Aim: To clarify the relationship between ambulatory glucose profile (AGP) indexes and standardized continuous glucose monitoring (CGM) metrics in patients with type 2 diabetes (T2D).
Methods: This is an exploratory, cross-sectional analysis of baseline data collected from a prospective, multicentre, 5-year follow-up observational study conducted and published previously by our group. The study participants were 999 outpatients with T2D who used CGM at baseline, and had no apparent history of cardiovascular disease. We investigated the relationship between average interquartile range (IQR) and time in range (TIR). We also calculated, for the first time, the cutoff values to achieve the TIR target values.
Results: In both the TIR more than 70% and TIR more than 90% achievement groups, the average IQR was notably small compared with the non-achievement groups. Particularly in comparison of the TIR quartiles, the average IQR became significantly smaller as the TIR became larger. The average IQR correlated negatively with TIR, and the cutoff values for TIR of more than 70% achievement and TIR of more than 90% achievement were an average IQR (>70%/>90%) of 2.13/1.85 mmol/L.
Conclusion: Our results showed a negative correlation between TIR and the range of blood glucose variations visually represented in AGP. The results also showed that the range of blood glucose variations in AGP is associated with indices of intraday and interday blood glucose variations and also with hypoglycaemia. Our results may provide new perspectives in the assessment and application of AGP in the clinical setting.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/dom.14550 | DOI Listing |
Chin J Integr Med
January 2025
Department of Ultrasound in Medicine, the Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, 310009, China.
Objective: To evaluate the therapeutic effects of Kuanxiong Aerosol (KXA) on ischemic stroke with reperfusion and elucidate the underlying pharmacological mechanisms.
Methods: In vivo pharmacological effects on ischemic stroke with reperfusion was evaluated using the transient middle cerebral artery occlusion (t-MCAO) mice model. To evaluate short-term outcome, 30 mice were randomly divided into vehicle group (n=15) and KXA group (n=15).
Langenbecks Arch Surg
January 2025
Department of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.
Purpose: Pancreatectomy patients often experience challenging fluctuations in blood glucose levels; therefore, they require a reliable monitoring system. This study aimed to determine the accuracy and acceptability of a continuous glucose monitoring (CGM) system compared with the intermittent capillary glucose test in patients who have undergone pancreatectomy.
Methods: Thirty non-diabetic pancreatectomy patients participated.
Vet Med Sci
January 2025
Department of Statistics, Faculty of Science, University of Muğla Sıtkı Koçman, Muğla, Turkey.
Background: There is a lack of data on the validation and diagnostic performance of the Freestyle Optium Neo-H (Freestyle) and Centrivet GK (Centrivet) devices for the diagnosis of hypoglycaemia, hyperglycaemia and hyperketonaemia in goats.
Objectives: The aim of the present study was to validate the Freestyle and Centrivet for the analysis of whole blood beta-hydroxybutyric acid (BHBA) and to validate the Freestyle for the analysis of whole blood glucose concentrations using the reference method (RM) in goat blood collected from the jugular and ear veins.
Methods: Venous blood samples were utilised to assess glucose and BHBA concentrations using the Freestyle, Centrivet and RM.
Nanomaterials (Basel)
December 2024
Guangdong Provincial Key Laboratory of Electronic Functional Materials and Devices, Huizhou University, Huizhou 516001, China.
Non-enzymatic glucose detection is an effective strategy to control the blood glucose level of diabetic patients. A novel hierarchical core-shell structure of nickel hydroxide shell coated copper hydroxide core based on copper foam (Ni(OH)@Cu(OH)-CF) was fabricated and derived from NiO@CuO-CF for glucose sensing. Cyclic voltammetry and amperometry experiments have demonstrated the efficient electrochemical catalysis of glucose under alkaline conditions.
View Article and Find Full Text PDFCells
December 2024
Beijing Institute of Brain Disorders, Capital Medical University, Beijing 100054, China.
Neurovascular coupling (NVC) refers to the process of local changes in cerebral blood flow (CBF) after neuronal activity, which ensures the timely and adequate supply of oxygen, glucose, and substrates to the active regions of the brain. Recent clinical imaging and experimental technology advancements have deepened our understanding of the cellular mechanisms underlying NVC. Pathological conditions such as stroke, subarachnoid hemorrhage, cerebral small vascular disease, and vascular cognitive impairment can disrupt NVC even before clinical symptoms appear.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!