A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

JEV-nanobarcode and colorimetric reverse transcription loop-mediated isothermal amplification (cRT-LAMP). | LitMetric

JEV-nanobarcode and colorimetric reverse transcription loop-mediated isothermal amplification (cRT-LAMP).

Mikrochim Acta

Center for Ecology and Environmental Toxicology, Chungbuk National University, 1 Chungdae-Ro, Seowon-Gu, Cheongju, 28644, South Korea.

Published: September 2021

Nucleic acid amplification tests (NAATs) are powerful tools for the Japanese encephalitis virus (JEV). We demonstrated highly sensitive, specific, and rapid detection of JEV by colorimetric reverse-transcription loop-mediated isothermal amplification (cRT-LAMP). Under optimized conditions, the RT-LAMP assay results showed that the limit of detection was approximately equivalent to 1 RNA genome copy/μL with an assay time of 30 min. The assay was highly specific to JEV when tested with other mosquito-borne virus panels (Zika virus and dengue virus types 2-4). The ability to detect JEV directly from crude human sample matrices (serum and urine) demonstrated the suitability of our JEV RT-LAMP for widespread clinical application. The JEV RT-LAMP provides combination of  rapid colorimetric determination of true-positive JEV RT-LAMP amplicons with our recently developed JEV-nanobarcodes, measured at absorbance wavelenght of 530 (A) and 650 (A), which have a limit of detection of 23.3 ng/μL. The AuNP:polyA-JEV RT-LAMP nanobarcodes exhibited superior capability for stabilizing the true-positive JEV RT-LAMP amplicons against salt-induced AuNP aggregation, which improved the evaluation of true/false positive signals in the assay. These advances enable to expand the use of RT-LAMP for point-of-care tests, which will greatly bolster JEV clinical programs. The JEV RT-LAMP nanobarcode assay targeting the envelope (E) gene and MgSO induced AuNP aggregation, indicated by an instant pink-to-violet colorimetric read-out.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-021-04986-9DOI Listing

Publication Analysis

Top Keywords

jev rt-lamp
16
jev
9
loop-mediated isothermal
8
isothermal amplification
8
amplification crt-lamp
8
rt-lamp
8
limit detection
8
true-positive jev
8
rt-lamp amplicons
8
aunp aggregation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!