Comparing the Clinical Utility and Diagnostic Performance of CSF P-Tau181, P-Tau217, and P-Tau231 Assays.

Neurology

From the Clinical Memory Research Unit (A.L., S.J., N.M.-C., S.P., C.C., E.S., O.H.), Department of Clinical Sciences, Lund University, Malmö; Department of Neurology (N.M.-C.) and Memory Clinic (S.P., E.S., O.H.), Skåne University Hospital, Lund; Wallenberg Centre for Molecular Medicine (N.M.-C.), Lund University, Sweden; ADx NeuroSciences NV (D.J., E.V.), Ghent, Belgium; and Eli Lilly and Company (J.L.D.), Indianapolis, IN.

Published: October 2021

Background And Objectives: Phosphorylated tau (p-tau) in CSF is considered an important biomarker in Alzheimer disease (AD) and has been incorporated in recent diagnostic criteria. Several variants exist, including p-tau at threonines 181 (p-tau181), 217 (p-tau217), and 231 (p-tau231). However, no studies have compared their diagnostic performance or association to β-amyloid (Aβ) and tau-PET. Understanding which p-tau variant to use remains an important yet answered question. We aimed to compare the diagnostic accuracy of p-tau181, p-tau217, and p-tau231 in CSF for AD and their association with Aβ and tau-PET.

Methods: A total of 629 participants in the Swedish BioFINDER-2 study were included (cognitively unimpaired, n = 334; Aβ-positive mild cognitive impairment, n = 84; AD dementia, n = 119; and non-AD disorders, n = 92). In addition to p-tau181 and p-tau217 measured using assays with the same detector antibodies from Eli Lilly (p-tau181, p-tau217) and p-tau231, we also included p-tau181 measurements from 2 commonly used assays (Innotest and Elecsys).

Results: Although all p-tau variants increased across the AD continuum, p-tau217 showed the greatest dynamic range (13-fold increase vs 1.9-5.4-fold increase for other p-tau variants for AD dementia vs non-AD). P-Tau217 showed stronger correlations with Aβ- and tau-PET ( < 0.0001). P-Tau217 exhibited higher accuracy than other p-tau variants for separating AD dementia from non-AD (area under the curve [AUC], 0.98 vs 0.88 [ < 0.0001] - 0.96 [ < 0.05]) and for identifying Aβ-PET (AUC, 0.86 vs 0.74 [ < 0.0001] and 0.83 [ < 0.001]) and tau-PET positivity (AUC, 0.94 vs 0.80-0.92, < 0.0001). Finally, p-Tau181 generally performed better than the other p-tau181 assays (e.g., AD dementia vs non-AD, AUC, 0.96 vs 0.88 [p-tau181] and 0.89 [p-tau181]; < 0.0001).

Discussion: CSF p-tau217 seems to be more useful than other included p-tau assays in the workup of AD. Varied results across p-tau181 assays highlights the importance of anti-tau antibodies for biomarker performance.

Classification Of Evidence: This study provides Class II evidence that p-tau217 provides higher diagnostic accuracy for diagnosis of AD dementia than p-tau181 or p-tau231.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8605616PMC
http://dx.doi.org/10.1212/WNL.0000000000012727DOI Listing

Publication Analysis

Top Keywords

p-tau181 p-tau217
16
p-tau217 p-tau231
12
p-tau variants
12
dementia non-ad
12
p-tau181
10
p-tau217
10
diagnostic performance
8
diagnostic accuracy
8
p-tau181 assays
8
p-tau
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!