Validation of pelvic magnetic resonance imaging as the method of choice to determine the distance to the anal margin in rectal cancer.

Cir Esp (Engl Ed)

Centro Europeo de Cirugía Colorrectal, Hospital Vithas Valencia 9 de Octubre, Valencia, España; La filiación de Miguel Ángel Lorenzo Liñán, Juan García Armengol, Gonzalo Pablo Martin Martin y José Vicente Roig Vila en el momento de la realización de este artículo era: Servicio de Cirugía General y del Aparato Digestivo, Consorcio Hospital General Universitario de Valencia, Valencia, España.

Published: September 2021

Introduction: Distance from anal verge of rectal tumors and their anatomical relationships contribute to determine the multidisciplinary therapeutic strategy based on the combination of radio-chemotherapy and radical surgery. Our aims are to investigate which is the most accurate method for the preoperative measuring of the distance from the anal verge in rectal tumors and if the pelvic MRI can substitute the classical instrumental methods.

Methods: Prospective study of diagnostic precision between flexible colonoscopy (FC), preoperative rigid rectosigmoidoscopy (pRR) and pelvic MRI in patients scheduled to radical surgery. Rigid intraoperative rectoscopy (iRR) was considered the reference test. The correlations between the different techniques and their determination coefficient as well as the intraclass correlation coefficient and the degree of agreement between the different tests were analyzed.

Results: 96 patients (65% males), mean age (SD): 68 (14.1) years were included. 72% received neoadjuvant treatment. The mean distance to the anal margin measured by FC=103.5mm, was significantly greater than others, which had similar values: pRR=81.1; MRI=77.4; iRR=82.9mm (P<.001). A significant intraclass correlation was observed and there was high agreement between all pre- and intraoperative measurements except for the performed by FC, which overestimated the results. MRI provided more individualized and accurate information.

Conclusions: There is variability between the measurement methods, being colonoscopy the least reliable. MRI offers objective, comparable, accurate and individualized values that can replace those obtained by pRR for tumors of any location in the rectum.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ciresp.2021.07.004DOI Listing

Publication Analysis

Top Keywords

distance anal
16
anal margin
8
anal verge
8
verge rectal
8
rectal tumors
8
radical surgery
8
pelvic mri
8
validation pelvic
4
pelvic magnetic
4
magnetic resonance
4

Similar Publications

Local Recurrence of Premalignant and Early Malignant Rectal Polyps Treated by TEM-A Single-Center Experience.

J Clin Med

December 2024

Department of Surgery, Rabin Medical Center-Hasharon Hospital, Faculty of Medicine, Tel Aviv University, Petach Tikva 49100, Israel.

Transanal endoscopic microsurgery (TEM) is a minimally invasive approach for excising rectal polyps, particularly those with high-grade dysplasia (HGD) or early-stage rectal cancer (T1). This study aimed to evaluate the recurrence risk and its associated factors in patients treated with TEM for HGD and T1 rectal tumors. A retrospective review was conducted on 79 patients who underwent TEM for rectal lesions at Rabin Medical Center-Hasharon Hospital from 2005 to 2019.

View Article and Find Full Text PDF

The integration of barcode technology with smartphones on paper-based analytical devices (PADs) presents a promising approach to bridging manual detection with digital interpretation and data storage. However, previous studies of 1D barcode approaches have been limited to providing only a "yes/no" response for analyte detection. Herein, a method of using barcode readout for semiquantitative signal detection on PADs has been achieved through the integration of barcode technology with a distance-based measurement concept on PADs.

View Article and Find Full Text PDF

Intramolecular distance-regulated G4 DNA enzymatic activity-based chromophotometric system for visual monitoring of diquat.

Anal Chim Acta

January 2025

Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, PR China. Electronic address:

Background: As global food production continues to surge, the widespread use of herbicides has also increased concurrently, posing challenges like health risks and environmental pollution. Traditional detection methods for pesticide residues, such as diquat (DQ), were hampered by limitations like high expenses, lengthy detection times and complex operations, restricting their practical application in rapid clinical diagnosis.

Results: In light of the pressing necessity for the identification of minute pesticide residues and the intrinsic constraints of small molecule analysis, a novel chromophotometric biosensor targeting small molecules was developed based on bi-epitopes on single antibody to immobilize two DQ-PAL, inhibiting the hybridization of DQ-PAL.

View Article and Find Full Text PDF

Flexible disk ultramicroelectrode: Facile preparation and high-resolution scanning electrochemical microscopy imaging.

Anal Chim Acta

January 2025

State Key Laboratory of Electroanalytical Chemistry, Jilin Province Key Laboratory of Low Carbon Chemical Power, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, Jilin, China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, Anhui, China. Electronic address:

Background: Scanning electrochemical microscopy (SECM) is a kind of scanning probe technology that enables the obtainment of surface morphology and electrochemical information by recording changes in Faraday current triggered by the movement of probe.

Results: In this work, flexible disk ultramicroelectrode (UME) with highly repeatable geometry are fabricated through a simple and universal strategy that involves vacuum pulling the glass capillaries inserted with platinum wire (gold wire, carbon fiber, etc.), followed by a rapidly heated sealing and polishing process.

View Article and Find Full Text PDF

Single cell combined with laser ablation ICP-MS to study cisplatinum (IV) loaded nanoparticles penetration pathways in osteosarcoma spheroids.

Anal Chim Acta

January 2025

Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo. C/ Julián Clavería 8, 33006, Oviedo, Spain; Health Research Institute of Asturias (ISPA), Avda de Roma s/n, 33011, Oviedo, Spain. Electronic address:

Background: 3D cellular structures have been considered the following step in the evaluation of drugs penetration after 2D cultures since they are more physiologically representative in cancer cell biology. Here the penetration capabilities of Pt (IV)-loaded ultrasmall iron oxide nanoparticles in 143B osteosarcoma multicellular spheroids of different sizes is conducted by a multidimensional quantitative approach. Single cell (SC) and imaging techniques (laser ablation, LA) coupled to inductively coupled plasma-mass spectrometry (ICP-MS) are used to visualize their penetration pathways and distribution in comparison to those of cisplatin.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!