A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Drill splatter in orthopaedic procedures and its importance during the COVID-19 pandemic : an experimental study. | LitMetric

Aims: During the COVID-19 pandemic, drilling has been classified as an aerosol-generating procedure. However, there is limited evidence on the effects of bone drilling on splatter generation. Our aim was to quantify the effect of drilling on splatter generation within the orthopaedic operative setting.

Methods: This study was performed using a Stryker System 7 dual rotating drill at full speed. Two fluid mediums (Videne (Solution 1) and Fluorescein (Solution 2)) were used to simulate drill splatter conditions. Drilling occurred at saw bone level (0 cm) and at different heights (20 cm, 50 cm, and 100 cm) above the target to simulate the surgeon 'working arm length', with and without using a drill guide. The furthest droplets were marked and the droplet displacement was measured in cm. A surgical microscope was used to detect microscopic droplets.

Results: Bone drilling produced 5 cm and 7 cm droplet displacement using Solutions 1 and 2, respectively. Drilling at 100 cm above the target produced the greatest splatter generation with a 95 cm macroscopic droplet displacement using Solution 2. Microscopic droplet generation was noticed at further distances than what can be macroscopically seen using Solution 1 (98 cm). Using the drill guide, there was negligible drill splatter generation.

Conclusion: Our study has shown lower than anticipated drill splatter generation. The use of a drill guide acted as a protective measure and significantly reduced drill splatter. We therefore recommend using a drill guide at all times to reduce the risk of viral transmission in the operative setting. Cite this article:  2021;2(9):752-756.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8479843PMC
http://dx.doi.org/10.1302/2633-1462.29.BJO-2021-0070.R1DOI Listing

Publication Analysis

Top Keywords

drill splatter
20
splatter generation
16
drill guide
16
droplet displacement
12
drill
10
covid-19 pandemic
8
bone drilling
8
drilling splatter
8
100 target
8
splatter
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!