Objectives: Magnetic resonance imaging (MRI) of the lungs is challenging for several reasons, mainly due to the respiratory motion, low proton density, and rapid T2* decay. Recent MR sequences with ultrashort TE (UTE) coupled with respiratory compensation promise to overcome these obstacles. So far, there are very few studies on the relevance of these sequences in children. The aim of the study was to compare the diagnostic value of a respiratory-self-gated three-dimensional UTE sequence versus a conventional respiratory-triggered T2-weighted turbo spin echo (T2-TSE) sequence in a pediatric collective.

Study Design: Seventy-one patients between 0 and 18 years of age, who were scheduled for a thoracic MRI based on diverse clinical indications, were examined on a 3T MRI system. The UTE and T2-TSE sequences were evaluated by two readers regarding quality features and visualization of eight common pathology patterns.

Results: The image quality of both sequences was equally high, with UTE depicting pleural and central bronchi more clearly. In pathologies, UTE was superior to T2-TSE for so-called "MR-negative pathologies", significant for air trapping, and in tendency for bullae and cysts. In all remaining pathologies, T2-TSE proved to be at least equivalent to UTE.

Conclusions: At present, UTE cannot serve as a universal replacement for conventional T2-TSE for all pathologies. It yields, however, a substantial benefit in the context of hyperinflation, emphysema, cysts, or pathologies of the bronchial system.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ppul.25664DOI Listing

Publication Analysis

Top Keywords

ute
6
t2-tse
5
pediatric lung
4
lung imaging
4
imaging ultrashort-te
4
ultrashort-te free
4
free breathing
4
breathing conventional
4
conventional sequence?
4
sequence? objectives
4

Similar Publications

A Comprehensive Review of Vision-Based Sensor Systems for Human Gait Analysis.

Sensors (Basel)

January 2025

Centre for Automation and Robotics (CAR UPM-CSIC), Escuela Técnica Superior de Ingeniería y Diseño Industrial (ETSIDI), Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, Spain.

Analysis of the human gait represents a fundamental area of investigation within the broader domains of biomechanics, clinical research, and numerous other interdisciplinary fields. The progression of visual sensor technology and machine learning algorithms has enabled substantial developments in the creation of human gait analysis systems. This paper presents a comprehensive review of the advancements and recent findings in the field of vision-based human gait analysis systems over the past five years, with a special emphasis on the role of vision sensors, machine learning algorithms, and technological innovations.

View Article and Find Full Text PDF

Metagenomics analysis has enabled the measurement of the microbiome diversity in environmental samples without prior targeted enrichment. Functional and phylogenetic studies based on microbial diversity retrieved using HTS platforms have advanced from detecting known organisms and discovering unknown species to applications in disease diagnostics. Robust validation processes are essential for test reliability, requiring standard samples and databases deriving from real samples and in silico generated artificial controls.

View Article and Find Full Text PDF

It is known that ultrashort echo time (UTE) magnetic resonance imaging (MRI) sequences can detect signals from water protons but not collagen protons in short T2 species such as cortical bone and tendons. However, whether collagen protons are visible with the zero echo time (ZTE) MRI sequence is still unclear. In this study, we investigated the potential of the ZTE MRI sequence on a clinical 3T scanner to directly image collagen protons via DO exchange and freeze-drying experiments.

View Article and Find Full Text PDF

Background: Early detection of changes in lumbar intervertebral disc degeneration (IVDD) has great clinical significance. T1rho and UTE-T2* relaxometry are capable of providing information about biochemical changes in IVDD. However, they have not been previously analyzed and compared directly in the same patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!