Workplace temperature screening has become standard practice during the SARS-CoV-2 pandemic. The objective was to determine the consistency of four temperature devices during exposure to simulated and actual environmental conditions reflective of a workplace. An infrared (IR) digital thermometer (accuracy(A)±0.2), IR laser thermometer (A±1), and thermal imaging camera (A±0.3) were used to measure forehead and tympanic (digital only) temperatures. The first experiment was conducted in a controlled simulated environment (-20 to 20 °C) with three participants (32-YOF, 27-YOM, 20-YOF). The second experiment used actual outdoor conditions (-0.48 to 45.6 °C) with two participants (32-YOF, 27-YOM). The tympanic measurement was the least impacted by environmental temperature (mean(±SD)): simulated (36.8(±0.18) °C) and actual (36.9(±0.16) °C). The thermal imaging camera had the lowest RMSE values (0.81-0.97 °C), with outdoor temperatures ranging from 0 to 45 °C. Environmental temperature influenced forehead temperature readings and required a resting period in a thermoneutral environment (5-9 min (-20 to -10 °C) to immediate (15-20 °C)).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8407948 | PMC |
http://dx.doi.org/10.1016/j.apergo.2021.103576 | DOI Listing |
Public Health Nurs
January 2025
Three Rivers Department of Rural Health, Charles Sturt University, Wagga Wagga, NSW, Australia.
Background: Rising global temperatures and increased use of personal protective equipment has led to increased risk of heat stress amongst healthcare professionals. This review synthesizes recent research on the impact of heat and heat mitigation strategies on healthcare professionals across disciplines and settings.
Method: Databases were systematically searched using keywords and data from included studies were extracted for content analysis.
Nat Commun
January 2025
Hunan University of Technology and Business, Changsha, China.
The exposure to extreme heat at workplaces poses substantial threat to human effort and manual labour. This becomes more prominent due to the global dispersion of labour-intensive production activities via trade. We combine a climate model with an input-output model to quantify the risks associated with trade-related occupational extreme heat exposure.
View Article and Find Full Text PDFJ Occup Environ Hyg
January 2025
Environmental Health Sciences Program, Department of Health Education and Promotion, East Carolina University, Greenville, North Carolina.
The wet bulb globe temperature (WBGT) index is the preferred environmental heat metric for occupational heat-related illness prevention but may not always be readily accessible in the workplace. Thus, there is a need for well-designed WBGT-based tools that are reliable, accessible, and inexpensive. A novel WBGT app prototype was developed to calculate the current and forecasted outdoor WBGT.
View Article and Find Full Text PDFJ Aerosol Sci
November 2024
National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH, 45226, United States.
Trace measurement of aerosol chemical composition in workplace atmospheres requires the development of high-throughput aerosol collectors that are compact, hand-portable, and can be operated using personal pumps. We describe the design and characterization of a compact, high flow, Turbulent-mixing Condensation Aerosol-in-Liquid Concentrator (TCALC) that allows direct collection of aerosols as liquid suspensions, for off-line chemical, biological, or microscopy analysis. The TCALC unit, measuring approximately 12 × 16 × 18 cm, operates at an aerosol sample flowrate of up to 10 L min, using rapid mixing of a hot flow saturated with water vapor and a cold aerosol sample flow, thereby promoting condensational growth of aerosol particles.
View Article and Find Full Text PDFHeliyon
December 2024
Department of Industrial Safety, Faculty of Mining, St. Petersburg Mining University, St. Petersburg, Russia.
Incorporating an illumination optimization plan into the worker safety management process in industrials is essential since the quality of workplace illumination has a significant impact on workers' well-being. The purpose of this study was to optimize illumination conditions in industrial workspaces using light-emitting diode (LED) technology with a color temperature of 6500 K and a CRI of 85 %. To accomplish this, the DIALux illumination simulation tool was utilized.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!