A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of complex congenital heart disease with prospective ECG-gated cardiac CT in a single heartbeat at low tube voltage (70 kV) and adaptive statistical iterative reconstruction in infants: a single center experience. | LitMetric

The purpose of this study is to evaluate the radiation dose, image quality, and diagnostic accuracy of prospective ECG-gated cardiac CT at 70 kV and adaptive statistical iterative reconstruction (ASIR), with a single source, 512 slice MDCT in the diagnosis of complex congenital heart disease in infants. We retrospectively evaluated 47 infants (ages 1 day to 353 days) with prospective ECG-gated cardiac CT that was performed on a single source 512 slice CT at low tube voltage (70 kV) using a wide detector aperture, adaptive statistical iterative reconstruction algorithm (ASIR), and specific reconstruction software reducing coronary motion artifacts (SnapShot Freeze). All cardiac images were obtained during the first pass of contrast material through the anatomic structures of interest and the targets for the center of the acquisition window were set 45% of the R-R interval during one cardiac cycle without sedation and breath-hold. The median effective dose measured in our study was 0.64 ± 0.16 mSv. The average subjective overall image quality score was 4.34 ± 0.31 (range 3-5). For the determination of objective image quality, Mean Noise (HU), SNR, and CNR values ​​emerged as 20.8, 28.7(for pulmonary artery), and 27.1, respectively. Diagnostic accuracy was 100% for the main purposes for the main clinical indication. During cardiac CT examination, pathologies in addition to cardiac anomalies were found in 9/47 of cases (7 severe airway obstructions,1 posterior diaphragmatic hernia, 1 vertebral anomaly). Prospective ECG-gated cardiac CT scan at 70 kV and ASIR in infants with complex CHD provides low radiation dose (submillisievert) in a single heartbeat with a good objective and subjective image quality. It also provides important benefits in the diagnosis of additional pathology.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-021-02390-1DOI Listing

Publication Analysis

Top Keywords

ecg-gated cardiac
16
image quality
16
prospective ecg-gated
12
adaptive statistical
12
statistical iterative
12
iterative reconstruction
12
complex congenital
8
congenital heart
8
heart disease
8
cardiac
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!