Background: Immediate loading of implant-supported full-arch rehabilitations has become routine practice when treating edentulous patients. The combination of static computer-aided implant surgery (s-CAIS) and digital prosthetic workflow could eliminate several treatment steps and facilitate prostheses delivery. The aim of this study is to evaluate the 1-year results of digitally prefabricated polymethyl methacrylate (PMMA) provisional prostheses without a cast for full-arch computer-assisted immediate loading.
Materials And Methods: A digital pre-operative treatment planning was realized for all patients: dental implants and screw-retained abutments were selected in the planning software and two surgical templates were fabricated for each patient. The first template was mucosa or teeth-supported to drill the holes for fixating pins, while the second template was placed after raising a full-thickness flap and was supported by pins as well as soft or hard tissue distal support. Furthermore, based on the surgical planning, interim prostheses were digitally designed and milled of PMMA resin blocks with subsequent pink resin veneering. Osteotomies and implant placement were performed through the surgical guides and all implants were immediately loaded with prefabricated full-arch interim prostheses directly connected to titanium copings with a flowable resin.
Results: A total of 55 dental implants were placed in ten patients. In all cases, interim prostheses allowed the insertion of titanium copings without the need of access hole enlargement or adaptation. All the prostheses had 1 year of functional loading to simulate the long provisional phase. No screw loosening occurred at the first removal of the prostheses after implant osseointegration. No fracture occurred during the whole period. After 1 year, the mean marginal bone loss level was 0.37 ± 0.06 mm, while the implant survival rate was 98.18% (n=54/55), with just one implant failing but not affecting final prosthesis delivery to the patient.
Conclusions: Within the limitations of the present study, the authors concluded that digitally prefabricated provisional prostheses for full-arch immediate loading with s-CAIS could be a valid alternative treatment modality. Milled PMMA restorations proved to be durable enough during the long provisional phase, without prosthetic complications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8419129 | PMC |
http://dx.doi.org/10.1186/s40729-021-00369-0 | DOI Listing |
J Dent
January 2025
The Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Ain Shams university, Organization of African Unity St. Abbasia - Cairo, Post No. 11566, Egypt. Electronic address:
Objectives: This study aims to compare the clinical performance of 3D printed endocrowns (ECs) and prefabricated zirconia crowns (PZRCs) in restoring pulpotomized primary molars, over 3, 6, and 12 months.
Methods: Thirty pulpotomized mandibular primary molars in 16 children aged 4-8 years were randomized with a 1:1 allocation ratio into two groups: group (A), PZRCs, and group (B), 3D-printed ECs. All restorations were evaluated for esthetic, functional, and biological properties using FDI criteria at 3-, 6-, and 12-month intervals.
Zhonghua Kou Qiang Yi Xue Za Zhi
January 2025
The post-and-core is a widely accepted method to restore endodontically treated teeth with compromised tooth structure. Currently, cast metal post-and-core systems and prefabricated fiber posts combined with composite resin cores are the most frequently options in dental clinical practice, but both also come with advantages and limitations. The development of computer-aided design/computer-aided manufacturing (CAD/CAM) custom fiber post-and-core represents one of the significant trends in the advancement of dentistry.
View Article and Find Full Text PDFJ Prosthet Dent
December 2024
Professor, Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, Wash. Electronic address:
Statement Of Problem: The angled screw channel (ASC) design has been well accepted for implant prostheses. However, investigation into the behavior of the ASC connection is sparse.
Purpose: The purpose of this in vitro study was to assess the effect of cyclic loading on the internal connection of an ASC system compared with straight access systems by measuring reverse torque values (RTVs) and using microcomputed tomography (µCT) imaging.
J Prosthet Dent
December 2024
Associate Professor and Department Head, Department of Prosthodontics, University of Ferrara, Ferrara, Italy.
The purpose of this article was to present a novel clinical workflow for the fabrication of complete dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) technology. The dental technique consists of 3 clinical steps and 2 laboratory phases that result in the production of 2 CAD-CAM milled complete denture bases with prefabricated teeth. The integration of analog and digital procedures and materials maximizes their benefits in the planning and fabrication of complete dentures, with the goal of improving clinical outcomes.
View Article and Find Full Text PDFJ Prosthet Dent
December 2024
Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand. Electronic address:
Statement Of Problem: Three-dimensional (3D) printing and milling technologies have been increasingly used in prosthodontic practice for fabricating digital prostheses. Nevertheless, evidence relating to the wear resistance of denture teeth fabricated using these methods is lacking.
Purpose: The purpose of this in vitro study was to compare the wear resistance exhibited by denture teeth fabricated using 3D printing and milling technologies with prefabricated denture teeth.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!