Fibula pro-tibia standard locking plate fixation in an ankle fracture saw bone model.

World J Orthop

Department of Orthopaedics, Royal Gwent Hospital, Newport NP20 2UB, United Kingdom.

Published: August 2021

Background: Locking plate fixation in osteoporotic ankle fractures may fail due to cut-out or metalwork failure. Fibula pro-tibia fixation was a technique prior to the advent of locking plates that was used to enhance stability in ankle fractures by achieving tri or tetra-cortical fixation. With locking plates, the strength of this fixation construct can be further enhanced. There is lack of evidence currently on the merits of tibia-pro-fibula augmented locking plate fixation of unstable ankle fractures.

Aim: To assess if there is increased strength to failure, in an ankle fracture saw bone model, with a fibula pro-tibia construct when compared with standard locking plate fixation.

Methods: Ten osteoporotic saw bones with simulated supination external rotation injuries were used. Five saw bones were fixed with standard locking plates whilst the other 5 saw bones were fixed with locking plates in a fibula pro-tibia construct. The fibula pro-tibia construct involved fixation with 3 consecutive locking screws applied across 3 cortices proximally from the level of the syndesmosis. All fixations were tested in axial external rotation to failure on an electromagnetic test frame (MTS 858 Mini-Bionix test machine, MTS Corp, Eden Praire, MN, United States). Torque at 30 degrees external rotation, failure torque, and external rotation angle at failure were compared between both groups and statistically analyzed.

Results: The fibula pro-tibia construct demonstrated a statistically higher torque at 30 degrees external rotation (4.421 ± 0.796 N/m 1.451 ± 0.467 N/m; -test = 0.000), as well as maximum torque at failure (5.079 ± 0.694N/m 2.299 ± 0.931 N/m; -test = 0.001) compared to the standard locking plate construct. The fibula pro-tibia construct also had a lower external rotation angle at failure (54.7 ± 14.5 67.7 ± 22.9).

Conclusion: The fibula pro-tibia locking plate construct demonstrates biomechanical superiority to standard locking plates in fixation of unstable ankle fractures in this saw bone model. There is merit in the use of this construct in patients with unstable osteoporotic ankle fractures as it may aid improved clinical outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8384614PMC
http://dx.doi.org/10.5312/wjo.v12.i8.548DOI Listing

Publication Analysis

Top Keywords

fibula pro-tibia
32
locking plate
24
external rotation
24
standard locking
20
locking plates
20
pro-tibia construct
20
ankle fractures
16
locking
12
plate fixation
12
bone model
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!