Background: Pulmonary embolism (PE) is one of the major causes of maternal mortality; however, its diagnosis based on clinical presentation is a significant challenge; therefore, imaging is required. This study aims to determine the nondiagnostic rate of PE in pregnant women who initially undergone computed tomographic pulmonary angiography (CTPA) or perfusion scan.
Materials And Methods: In this cross-sectional study, all pregnant or 6-week postpartum women with clinical suspicion of PE were evaluated and underwent CTPA or perfusion scan between March 2017 and June 2019. The nondiagnostic rate of each method was defined as the outcome of this study.
Results: One hundred and eighty-two women with a clinical suspicion of PE were included, among which the initial imaging method was CTPA in 122 (67.03%) and perfusion scan in 60 (32.97%) women. The nondiagnostic imaging for CTPA was significantly lower than the perfusion scan (9 cases (7.4%) versus 25 cases (41.7%), respectively). Logistic regression assessment revealed a statistical outcome by controlling the confounders including gestational trimester at diagnosis, hypertension, ejection fraction, and tachycardia (odds ratio 15.911, 95% confidence interval: 5.177-48.897, < 0.001).
Conclusion: Based on the current study, CTPA is superior to perfusion scans to diagnose PE among pregnant or postpartum women with normal chest X-ray suspicion for PE.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8384013 | PMC |
http://dx.doi.org/10.4103/jrms.JRMS_113_20 | DOI Listing |
R I Med J (2013)
February 2025
Alpert Medical School of Brown University, Department of Medicine, Division of Cardiology, Rhode Island Hospital.
Cardiac Positron Emission Tomography (PET) can be used for the assessment of myocardial perfusion. Compared to other cardiac imaging techniques, notably Single Photon Emission Computer Tomography (SPECT), cardiac PET offers superior image resolution, higher accuracy, quantitative measures of myocardial perfusion, lower radiation exposure, and shorter image acquisition time. However, PET tends to be costlier and less widely available than SPECT due to the specialized equipment needed for generating the necessary radiotracers.
View Article and Find Full Text PDFSci Rep
January 2025
Australian Dysautonomia and Arrhythmia Research Collaborative, Adelaide, SA, Australia.
Cognitive dysfunction is frequently reported in individuals with postural orthostatic tachycardia syndrome (POTS), possibly resulting from reduced cerebral blood flow (CBF). We used brain SPECT, an accessible imaging modality that has not been systematically evaluated in this patient group. Retrospective review of participants from our registry was undertaken to identify those who had a brain SPECT performed for investigation of cognitive dysfunction.
View Article and Find Full Text PDFMed Phys
January 2025
Institute for Medical Engineering, Otto von Guericke University Magdeburg, Magdeburg, Germany.
Background: The success of embolization, a minimally invasive treatment of liver cancer, could be evaluated in the operational room with cone-beam CT by acquiring a dynamic perfusion scan to inspect the contrast agent flow.
Purpose: The reconstruction algorithm must address the issues of low temporal sampling and higher noise levels inherent in cone-beam CT systems, compared to conventional CT.
Methods: Therefore, a model-based perfusion reconstruction based on the time separation technique (TST) was applied.
Eur J Neurol
February 2025
IRCCS Istituto delle Scienze Neurologiche di Bologna, Department of Neurology and Stroke Center, Maggiore Hospital, Bologna, Italy.
Background: To investigate the relevance of hyperperfusion on computerised perfusion imaging (CTP) in the emergency setting in people with non-convulsive status epilepticus (NCSE) and previous stroke, to derive relevant aspects on the epileptogenic focus and the network recruited for NCSE propagation.
Methods: We enrolled consecutive adult patients with acute-onset NCSE and a previous stroke at a single institution undergoing CTP and EEG during symptoms. All patients underwent standard imaging including CT, CTP, CT angiograms and standard EEG within 30 min from hospital arrival.
Radiol Clin North Am
March 2025
Department of Radiology, University of California San Diego, La Jolla, CA, USA. Electronic address:
Chronic thromboembolic pulmonary hypertension (CTEPH) is pulmonary hypertension secondary to chronic obstruction of pulmonary arteries by organized thromboemboli. Echocardiography and Echocardiography and ventilation/perfusion (V/Q) scan are the initial screening examinations for CTEPH; the diagnosis is often missed on computed tomography (CT). Imaging findings of chronic thromboembolic pulmonary disease overlap with those of acute pulmonary embolism, and radiologists should evaluate for the presence of concurrent chronic disease in all cases of acute pulmonary embolism detected on CT pulmonary angiography.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!