The aim of this study was to study the incidence of preanalytical errors in the clinical chemistry laboratory attached to a tertiary care hospital.  The study was conducted in a clinical chemistry laboratory using the samples and forms received for analysis. Five hundred random samples were analyzed using a predefined set of quality indicators (QIs) over a period of 3 months. The incidence of each preanalytical error was described as a percentage of the total samples analyzed in the study.  Individual QIs were assigned values as 0 and 1 and were used to assess each sample; 0 if the error was present, and 1 if absent. The incidence of each preanalytical error was described as a percentage of the total samples analyzed in the study.  Out of the 500 samples observed, 138 samples were error free, while 21 samples had the maximum number of errors, that is, 6. The error committed most often was the omission of provisional diagnosis being mentioned on the requisition form. No preanalytical error was observed for QIs: selecting the appropriate blood collection vial or storage of sample.  This study confirms that error rate in the preanalytical phase is high and vastly ignored. Errors committed here may be overlooked, given the large number of samples received in the clinical laboratory of a tertiary center. To reduce these errors, the laboratory should provide training to all workers involved in the preanalytical phase. Daily or weekly QI scores should be recorded to assess and rectify shortcomings, thereby improving patient care.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8409113PMC
http://dx.doi.org/10.1055/s-0041-1729473DOI Listing

Publication Analysis

Top Keywords

preanalytical phase
12
incidence preanalytical
12
samples analyzed
12
preanalytical error
12
quality indicators
8
clinical chemistry
8
chemistry laboratory
8
samples
8
error described
8
described percentage
8

Similar Publications

The objective of this study is to develop an HPLC-UV method for the cost-effective and quantitative determination of vitamin D3 in food, even in the presence of vitamin D2, with a specific focus on egg yolk. During method development, the performance of three stationary phases in resolving the peak of vitamin D2 from that of vitamin D3 was investigated. The physicochemical properties of these phases differed particularly in the extent of hydrophobicity and silanophilic activity, including a GraceSmart RP C18 column without silanol endcapping, a Robusta RP C18 column with silanol endcapping, and a Waters Xbridge RP C18 column with ethylene-bridged hybrid (BEH) particle technology.

View Article and Find Full Text PDF

Methotrexate (MTX) is an antifolic agent used in the first line of anti-inflammatory disease treatment and some oncologic issues. The metabolism of MTX is rapid, and the MTX concentration in the blood is not significant 24 h after administration. Unlike this, methotrexate polyglutamates (MTXPGs) can be informative biomarkers of drug exposure.

View Article and Find Full Text PDF

The Working Group Preanalytical Phase of the European Federation of Clinical Chemistry and Laboratory Medicine advises suppressing haemolysis-sensitive tests when haemolysis is clinically significant, as improper specimen handling can rupture red blood cells, increasing potassium levels. Thus, a correctly repeated blood sample should show lower potassium levels than a haemolysed one. This study aimed to determine the prevalence of haemolysed samples with potassium levels below the reference range and whether this predicts hypokalemia in repeated collections.

View Article and Find Full Text PDF

Background: Grossly lipaemic samples are a significant cause of analytical errors, potentially impacting patient care. The causes of lipaemia are varied and often unavoidable, while methods to reduce lipaemia through gold-standard ultracentrifugation are limited by availability, transportation and cost. Benchtop centrifugation has been proposed as an alternative method to reduce lipaemia.

View Article and Find Full Text PDF

Objectives: Urinalysis is widely used and is also frequently requested in emergency situations for screening hypovolemia, urinary tract infections, diabetes, ketoacidosis and hematuria. Our aim was to evaluate the impact of reporting urinary sediment in emergency department specimens with the Sysmex UN system.

Methods: We evaluated urinalyses requested by the emergency department over a three-month period and examined red blood cell count interference, compared leukocyte esterase dipsticks to cytofluorimetric leukocyte count and nitrites to cytofluorimetric bacterial count.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!