Influence of balloon location during proximal optimization technique (POT): A finite element analysis.

J Biomech

Beijing Anzhen Hospital, Capital Medical University, No.2 Anzhen Road, Chaoyang District, Beijing, China. Electronic address:

Published: October 2021

Proximal Optimization Technique (POT)is a post-expansion technique that must be completed after single-stent implantation for the coronary bifurcation. The optimal location for the distal balloon shoulder during POT remains debatable. In the present study, the finite element method is applied to simulate POT after single-stent implantation in the coronary bifurcation. Three different balloon locations based on the distal shoulder relative to the carina cut plane were analyzed: 1) "proximal":1mm before carina cut plane; 2) "standard": at the carina cut plane; and 3) "distal": 1 mm after the carina cut plane. The computational results showed differences in stent, vessel morphology, and vessel wall stress due to the different balloon locations. However, when distal balloon shoulder was located between two adjacent stent rings, it formed the distal cell of the stent, the best stent apposition, least stent structs obstruction at SB ostial. Moreover, best opening effect of distal cell of the stent can be achieved, with the least damage to the vessel wall.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2021.110703DOI Listing

Publication Analysis

Top Keywords

carina cut
16
cut plane
16
proximal optimization
8
optimization technique
8
finite element
8
single-stent implantation
8
implantation coronary
8
coronary bifurcation
8
distal balloon
8
balloon shoulder
8

Similar Publications

Lung cancer is the leading cause of cancer deaths in men and women in the United States. Accurate staging is needed to determine prognosis and devise effective treatment plans. The International Association for the Study of Lung Cancer (IASLC) has made multiple revisions to the tumor, node, metastasis (TNM) staging system used by the Union for International Cancer Control and the American Joint Committee on Cancer to stage lung cancer.

View Article and Find Full Text PDF
Article Synopsis
  • * Analyzing 111 lesions from 168 patients, the research found three key geometric parameters—SB diameter, BP-CT length, and dPOC—that were significant predictors of SB compromise, with corresponding cutoff values established.
  • * The results revealed that as the OCT risk score increased based on these parameters, the likelihood of SB compromise also increased significantly, demonstrating the predictive capability of OCT in this context.
View Article and Find Full Text PDF

Objective: This study aimed to find the radiographic characteristics for the detection of hypertrophic cardiomyopathy (HCM) and congestive heart failure (CHF) in cats.

Animals: Healthy cats (n = 35) and HCM cats with (21) and without (22) CHF.

Methods: On radiography, the cardiac size using vertebral heart score, left atrium enlargement (LAE), and dilation of the pulmonary vessels were assessed.

View Article and Find Full Text PDF

The Agreement between Radiography and Fluoroscopy as Diagnostic Tools for Tracheal Collapse in Dogs.

Animals (Basel)

April 2023

Department of Clinical Sciences and Public Health, Faculty of Veterinary Science, Mahidol University, Nakhon Pathom 73170, Thailand.

Tracheal collapse is a common disease in small, middle-aged dogs, and imaging tools are essential for its diagnosis. Radiography and fluoroscopy are the main diagnostic modalities used, but their agreement in different regions is not well documented. In this study, the agreement between thoracic radiography and fluoroscopy in tracheal collapse was investigated in 29 dogs.

View Article and Find Full Text PDF

Purpose: Local impedance (LI) measurement from an ablation catheter is useful in predicting lesion size and acute success of pulmonary vein isolation (PVI). The LI variation can be described by absolute LI drop (ΔLID) or ΔLID/initial LI (%LID). We evaluated the utility of these parameters in predicting acute lesion durability during PVI using a novel catheter capable of measuring both LI and contact force (CF).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!