A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Tidal volume measurements via transthoracic impedance waveform characteristics: The effect of age, body mass index and gender. A single centre interventional study. | LitMetric

Tidal volume measurements via transthoracic impedance waveform characteristics: The effect of age, body mass index and gender. A single centre interventional study.

Resuscitation

Norwegian National Advisory Unit for Prehospital Emergency Medicine (NAKOS), Oslo University Hospital - Ullevål and University of Oslo, Po Box 4956 Nydalen, N-0424 Oslo, Norway; Air Ambulance Department, Division of Prehospital Services, Oslo University Hospital, Oslo, Norway.

Published: October 2021

Background And Aim: Measuring tidal volumes (TV) during bag-valve ventilation is challenging in the clinical setting. The ventilation waveform amplitude of the transthoracic impedance (TTI-amplitude) correlates well with TV for an individual, but poorer between patients. We hypothesized that TV to TTI-amplitude relations could be improved when adjusted for morphometric variables like body mass index (BMI), gender or age, and that TTI-amplitude cut-offs for ventilations with adequate TV (>400ml) could be established.

Materials And Methods: Twenty-one consenting adults (9 female, and 9 overall overweight) during positive pressure ventilation in anaesthesia before scheduled surgery were included. Seventeen ventilator modes were used (⩾ five breaths per mode) to adjust different TVs (150-800 ml), ventilation frequencies (10-30 min) and insufflation times (0.5-3.5 s). TTI from the defibrillation pads was filtered to obtain ventilation TTI-amplitudes. Linear regression models were fitted between target and explanatory variables, and compared (coefficient of determination, R).

Results: The TV to TTI-amplitude slope was 1.39 Ω/l (R=0.52), with significant differences (p<0.05) between male/female (1.04 Ω/l vs 1.84 Ω/l) and normal/overweight subjects (1.65 Ω/l vs 1.04 Ω/l). The median (interquartile range) TTI-amplitude cut-off for adequate TV was 0.51 Ω(0.14-1.20) with significant differences between males and females (0.58 Ω/0.39 Ω), and normal and overweight subjects (0.52 Ω/0.46 Ω). The TV to TTI-amplitude model improved (R=0.66) when BMI, age and gender were included.

Conclusions: TTI-amplitude to TV relations were established and cut-offs for ventilations with adequate TV determined. Patient morphometric variables related to gender, age and BMI explain part of the variability in the measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.resuscitation.2021.08.041DOI Listing

Publication Analysis

Top Keywords

transthoracic impedance
8
body mass
8
ventilation
5
tidal volume
4
volume measurements
4
measurements transthoracic
4
impedance waveform
4
waveform characteristics
4
characteristics age
4
age body
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!