A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preliminary results of Preserflo Microshunt versus Preserflo Microshunt and Ologen implantation. | LitMetric

Purpose: To report preliminary 6-month results on the use of the Preserflo Microshunt implant with and without Ologen in 50 pseudophakic eyes with moderate to advanced primary open-angle glaucoma (POAG).

Methods: Fifty pseudophakic eyes underwent ab externo Preserflo Microshunt implantation. Data was gathered retrospectively and two groups were then created, group A with application of MMC 0.2 mg/ml and group B with MMC 0.2 mg/ml and Ologen collagen matrix (OCM) implantation. Absolute success was regarded as the percentage of eyes achieving: a) 5 ≤ intraocular pressure (IOP) ≤ 13 mmHg, b) 5 ≤ IOP ≤ 16 mmHg, and c) 5 ≤ IOP ≤ 21 mmHg without additional medication or surgery and qualified success was regarded as the percentage of eyes achieving a) IOP ≤ 13 mmHg, b) IOP ≤ 16 mmHg, and c) IOP ≤ 21 mmHg with or without medication. Evaluation was performed using a log-rank Kaplan-Meier test. A scatterplot analysis presented the treatment effect data of all eyes with a minimum of 20% IOP reduction per case. Failure was defined as requiring additional surgery, IOP greater than 21 mmHg with or without medication and failure to reach 20% IOP reduction.

Results: Mean postoperative IOP was significantly lower in both groups. IOP decreased by 49.06% in group A and by 53.01% in group B at 6 months (P < 0.88), respectively. Medication use was lower in both groups (Wilcoxon test, P < 0.001). The absolute and qualified success rates were not statistically significant between the groups (all P > 0.05). Cumulative IOP results per case were not statistically different in group A compared with group B. One revision surgery in group A (4% failure rate) and three in group B (12% failure rate) were performed.

Conclusions: Both groups showed equal results in terms of cumulative and mean IOP reduction, medication reduction as well as in absolute and qualified success rates. No significant difference was found in any parameters tested between Preserflo Microshunt with MMC 0.2 mg/ml and with or without OCM implantation at 6 months. Long-term follow-up is required to further evaluate this data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8414750PMC
http://dx.doi.org/10.1186/s40662-021-00253-3DOI Listing

Publication Analysis

Top Keywords

preserflo microshunt
16
pseudophakic eyes
8
mmc 02 mg/ml
8
success regarded
8
regarded percentage
8
percentage eyes
8
eyes achieving
8
20% iop
8
eyes
5
iop
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!