Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The aim of this study was to compare the enucleation performances of four different types of laser devices in an ex-vivo experiment: a novel, pulsed Tm:YAG solid-state laser evaluation model (p-Tm:YAG), chopped thulium fibre laser (TFL), low-power Ho:YAG laser (LP-Ho:YAG), and a high-power Ho:YAG laser (HP-Ho:YAG).
Methods: Our primary aim was to endoscopically separate the fascial layers of a porcine belly using laser fibres within a time period of 60 s. The size of a "tissue pocket" was assessed numerically. The enucleation characteristics reflecting the surgeon's experience were evaluated via the NASA Task Load Index (TLX) questionnaire and a questionnaire based on Likert scale.
Results: HP-Ho:YAG achieved with the available laser settings the largest overall "tissue pocket" (31.5 cm) followed by p-Tm:YAG (15 cm), TFL (12 cm), and LP-Ho:YAG (6 cm). The coagulation performances of p-Tm:YAG and TFL were rated the best. In the performance evaluation by the Likert questionnaire, HP-Ho:YAG (average score of 4.06) was rated highest, followed by p-Tm:YAG (3.94), TFL (3.38), and LP-Ho:YAG (3.25). The evaluation of the NASA-TLX performance questionnaire revealed average scores for HP-Ho:YAG, LP-Ho:YAG, TFL and p-Tm:YAG of 4.38, 4.09, 3.92 and 3.90, respectively.
Conclusion: We are the first to compare different laser devices and settings in an ex-vivo study. We found that the surgeons were most satisfied with the HP-Ho:YAG laser device, followed by the p-Tm:YAG. These findings could be highly relevant for future research and for the practical utilisation of laser systems in endourology.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8921029 | PMC |
http://dx.doi.org/10.1007/s00345-021-03825-z | DOI Listing |