Aims: Iron deficiency (ID) is associated with poor prognosis regardless of anaemia. Intravenous iron improves quality of life and outcomes in patients with ID and heart failure (HF) with reduced ejection fraction (HFrEF). In the Swedish HF registry, we assessed (i) frequency and predictors of ID testing; (ii) prevalence and outcomes of ID with/without anaemia; (iii) use of ferric carboxymaltose (FCM) and its predictors in patients with ID.
Methods And Results: We used multivariable logistic regressions to assess patient characteristics independently associated with ID testing/FCM use, and Cox regressions to assess risk of outcomes associated with ID. Of 21 496 patients with HF and any ejection fraction enrolled in 2017-2018, ID testing was performed in 27%. Of these, 49% had ID and more specifically 36% had ID-/anaemia-, 15% ID-/anaemia+, 29% ID+/anaemia-, and 20% ID+/anaemia+ (48%, 39%, 13%, 30% and 18% in HFrEF, respectively). Risk of recurrent all-cause hospitalizations was higher in patients with ID regardless of anaemia. Of 1959 patients with ID, 19% received FCM (24% in HFrEF). Important independent predictors of ID testing and FCM use were anaemia, higher New York Heart Association class, having HFrEF, and referral to HF specialty care.
Conclusion: In this nationwide HF registry, ID testing occurred in only about a quarter of the patients. Among tested patients, ID was present in one half, but only one in five patients received FCM indicating low adherence to current guidelines on screening and treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ejhf.2338 | DOI Listing |
Diabetes Ther
December 2024
Patient Author, Heart Sistas, North Lauderdale, FL, USA.
Type 2 diabetes (T2D) frequently coexists with cardiorenal complications. Therefore, a holistic approach to patient management is required, with specialists such as primary care physicians, cardiologists, endocrinologists, and nephrologists working together to provide patient care. Although glycemic control is important in the management of T2D, patients with T2D and acceptable glycemic control are still at risk from cardiovascular (CV) events such as stroke, heart attack, and heart failure (HF).
View Article and Find Full Text PDFPacing Clin Electrophysiol
December 2024
Arrhythmia Unit, Department of Cardiology, Hospital Juan Ramón Jiménez, Huelva, Spain.
Background: Interventricular dyssynchrony derived from the classic non-physiological stimulation (n-PS) of the right ventricle (RV) is a known cause of left ventricular dysfunction (LVDys).
Methods: This was a prospective descriptive single-center study. We analyzed patients who develop LVDys with n-PS, and the results after upgrading to conduction system pacing (CSP).
J Echocardiogr
December 2024
Department of Cardiology, Lebanese American University Medical Center - Rizk Hospital, Beirut, Lebanon.
Left atrial strain (LAS) was recently introduced as a parameter that reflects on left atrial function. Consequently, changes in LAS can inform the development of cardiovascular diseases, hence providing a window for non-invasive and cost-effective testing of these diseases and their complications at early stages of development, potentially offering a segway towards preventive interventions. LAS has yet to be implemented into standard practice.
View Article and Find Full Text PDFZ Gerontol Geriatr
December 2024
2. Med. Abteilung, Klinik Landstraße, Juchgasse 25, 1030, Wien, Österreich.
Background: Little is known about how younger and older hospitalized patients differ with respect to reasons for admission, comorbidities, diagnostics, treatment and intercurrent problems.
Objective: The aim of the study was to compare the previously named characteristics in the clinical profile of patients > 90 years old (nonagenarians) with a control group of patients 70-75 years old admitted to an emergency hospital department for internal medicine and cardiology.
Material And Method: The study included all consecutive nonagenarians and gender-matched control patients who were admitted during 2011.
Pacing Clin Electrophysiol
December 2024
Department of Cardiology II - Electrophysiology, University Hospital Münster, Münster, Germany.
Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.
Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.
Results: The majority of patients (87.